Ordering
7350024483253
1 piece
85364900
Popular Downloads
Dimensions
22.5 mm
120 mm
120 mm
0.19 kg
Technical
Expansion relay - No monitoring of two channel fault
Start/test input
No Time Delay
24 V DC
5 A
6 A
IP20
Crimped Pin 1x0.2...3.3 mm²
Crimped Pin 2x0.2...1.5 mm²
Flexible with Ferrule 1x0.2...3.3 mm²
Flexible with Ferrule 2x0.2...1.5 mm²
Solid 1x0.2...3.3 mm²
Solid 2x0.2...1.5 mm²
Crimped Pin 1x0.2...3.3 mm²
Crimped Pin 2x0.2...1.5 mm²
Flexible with Ferrule 1x0.2...3.3 mm²
Flexible with Ferrule 2x0.2...1.5 mm²
Solid 1x0.2...3.3 mm²
Solid 2x0.2...1.5 mm²
0.7 N·m
6.5 mm
M3.5
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
IS0 13849
Technical UL/CSA
Crimped Pin 1x 24-12 AWG
Crimped Pin 2x 24-16 AWG
Flexible with Ferrule 1x 24-12 AWG
Flexible with Ferrule 2x 24-16 AWG
Solid 1x 24-12 AWG
Solid 2x 24-16 AWG
Crimped Pin 1x 24-12 AWG
Crimped Pin 2x 24-16 AWG
Flexible with Ferrule 1x 24-12 AWG
Flexible with Ferrule 2x 24-16 AWG
Solid 1x 24-12 AWG
Solid 2x 24-16 AWG
Environmental
Operation -25 ... +65 °C
Storage -40 ... +70 °C
Operation -25 ... +65 °C
Storage -40 ... +70 °C
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Certificates and Declarations
Container Information
box 1 piece
125 mm
31 mm
129 mm
0.251 kg
7350024483253
36 piece
280 mm
395 mm
210 mm
9.3 kg
External Classifications and Standards
K
EC001449 - Device for monitoring of safety-related circuits
EC001449 - Device for monitoring of safety-related circuits
EC001449 - Device for monitoring of safety-related circuits
V11.0 : 27371819
39122331
2712519
3860816

Ordering
7350024483260
1 piece
85364900
Popular Downloads
Dimensions
22.5 mm
120 mm
120 mm
0.19 kg
Technical
Expansion relay - No monitoring of two channel fault
Start/test input
No Time Delay
24 V DC
5 A
6 A
IP20
Crimped Pin 1x0.2...3.3 mm²
Crimped Pin 2x0.2...1.5 mm²
Flexible with Ferrule 1x0.2...3.3 mm²
Flexible with Ferrule 2x0.2...1.5 mm²
Solid 1x0.2...3.3 mm²
Solid 2x0.2...1.5 mm²
Crimped Pin 1x0.2...3.3 mm²
Crimped Pin 2x0.2...1.5 mm²
Flexible with Ferrule 1x0.2...3.3 mm²
Flexible with Ferrule 2x0.2...1.5 mm²
Solid 1x0.2...3.3 mm²
Solid 2x0.2...1.5 mm²
0.7 N·m
6.5 mm
M3.5
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
IS0 13849
Technical UL/CSA
Crimped Pin 1x 24-12 AWG
Crimped Pin 2x 24-16 AWG
Flexible with Ferrule 1x 24-12 AWG
Flexible with Ferrule 2x 24-16 AWG
Solid 1x 24-12 AWG
Solid 2x 24-16 AWG
Crimped Pin 1x 24-12 AWG
Crimped Pin 2x 24-16 AWG
Flexible with Ferrule 1x 24-12 AWG
Flexible with Ferrule 2x 24-16 AWG
Solid 1x 24-12 AWG
Solid 2x 24-16 AWG
Environmental
Operation -25 ... +65 °C
Storage -40 ... +70 °C
Operation -25 ... +65 °C
Storage -40 ... +70 °C
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Certificates and Declarations
Container Information
box 1 piece
125 mm
31 mm
129 mm
0.251 kg
7350024483260
36 piece
280 mm
395 mm
210 mm
9.3 kg
External Classifications and Standards
K
EC001449 - Device for monitoring of safety-related circuits
EC001449 - Device for monitoring of safety-related circuits
EC001449 - Device for monitoring of safety-related circuits
V11.0 : 27371819
39122331
2712520
3860817

Ordering
7350024483291
1 piece
85364900
Popular Downloads
Dimensions
22.5 mm
120 mm
120 mm
0.214 kg
Technical
Safety relay for monitoring of safety devices
Start/test input, Manual/Auto reset selectable by switch
No Time Delay
120 ... 375 V DC
85 ... 265 V AC
120 ... 375 V DC
85 ... 265 V AC
5 A
6 A
IP20
Crimped Pin 1x0.2...3.3 mm²
Crimped Pin 2x0.2...1.5 mm²
Flexible with Ferrule 1x0.2...3.3 mm²
Flexible with Ferrule 2x0.2...1.5 mm²
Solid 1x0.2...3.3 mm²
Solid 2x0.2...1.5 mm²
Crimped Pin 1x0.2...3.3 mm²
Crimped Pin 2x0.2...1.5 mm²
Flexible with Ferrule 1x0.2...3.3 mm²
Flexible with Ferrule 2x0.2...1.5 mm²
Solid 1x0.2...3.3 mm²
Solid 2x0.2...1.5 mm²
0.7 N·m
6.5 mm
M3.5
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
IS0 13849
Technical UL/CSA
Crimped Pin 1x 24-12 AWG
Crimped Pin 2x 24-16 AWG
Flexible with Ferrule 1x 24-12 AWG
Flexible with Ferrule 2x 24-16 AWG
Solid 1x 24-12 AWG
Solid 2x 24-16 AWG
Crimped Pin 1x 24-12 AWG
Crimped Pin 2x 24-16 AWG
Flexible with Ferrule 1x 24-12 AWG
Flexible with Ferrule 2x 24-16 AWG
Solid 1x 24-12 AWG
Solid 2x 24-16 AWG
Environmental
Operation -25 ... +65 °C
Storage -40 ... +70 °C
Operation -25 ... +65 °C
Storage -40 ... +70 °C
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Certificates and Declarations
Container Information
box 1 piece
125 mm
31 mm
129 mm
0.275 kg
7350024483291
36 piece
280 mm
395 mm
210 mm
10.2 kg
External Classifications and Standards
K
EC001449 - Device for monitoring of safety-related circuits
EC001449 - Device for monitoring of safety-related circuits
EC001449 - Device for monitoring of safety-related circuits
V11.0 : 27371819
39122331
2712523
3860820

Ordering
7350024483307
1 piece
85364900
Popular Downloads
Dimensions
22.5 mm
120 mm
120 mm
0.207 kg
Technical
Safety relay for monitoring of two-hand devices
Start/test input, Manual/Auto reset selectable by switch
No Time Delay
24 V DC
5 A
6 A
IP20
Crimped Pin 1x0.2...3.3 mm²
Crimped Pin 2x0.2...1.5 mm²
Flexible with Ferrule 1x0.2...3.3 mm²
Flexible with Ferrule 2x0.2...1.5 mm²
Solid 1x0.2...3.3 mm²
Solid 2x0.2...1.5 mm²
Crimped Pin 1x0.2...3.3 mm²
Crimped Pin 2x0.2...1.5 mm²
Flexible with Ferrule 1x0.2...3.3 mm²
Flexible with Ferrule 2x0.2...1.5 mm²
Solid 1x0.2...3.3 mm²
Solid 2x0.2...1.5 mm²
0.7 N·m
6.5 mm
M3.5
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
IS0 13849
Technical UL/CSA
Crimped Pin 1x 24-12 AWG
Crimped Pin 2x 24-16 AWG
Flexible with Ferrule 1x 24-12 AWG
Flexible with Ferrule 2x 24-16 AWG
Solid 1x 24-12 AWG
Solid 2x 24-16 AWG
Crimped Pin 1x 24-12 AWG
Crimped Pin 2x 24-16 AWG
Flexible with Ferrule 1x 24-12 AWG
Flexible with Ferrule 2x 24-16 AWG
Solid 1x 24-12 AWG
Solid 2x 24-16 AWG
Environmental
Operation -25 ... +65 °C
Storage -40 ... +70 °C
Operation -25 ... +65 °C
Storage -40 ... +70 °C
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Certificates and Declarations
Container Information
box 1 piece
125 mm
31 mm
129 mm
0.268 kg
7350024483307
36 piece
280 mm
395 mm
210 mm
9.9 kg
External Classifications and Standards
K
EC001452 - Two-hand control relay
EC001452 - Two-hand control relay
EC001452 - Two-hand control relay
V11.0 : 27371821
39122331
2712524
3860821

Ordering
7350024483338
1 piece
85364900
Popular Downloads
Dimensions
22.5 mm
120 mm
120 mm
0.207 kg
Technical
Safety relay for monitoring of safety devices
Start/test input, Manual/Auto reset selectable by switch
OFF-Delay
1.5 seconds
24 V DC
3 A
3 A
IP20
Crimped Pin 1x0.2...3.3 mm²
Crimped Pin 2x0.2...1.5 mm²
Flexible with Ferrule 1x0.2...3.3 mm²
Flexible with Ferrule 2x0.2...1.5 mm²
Solid 1x0.2...3.3 mm²
Solid 2x0.2...1.5 mm²
Crimped Pin 1x0.2...3.3 mm²
Crimped Pin 2x0.2...1.5 mm²
Flexible with Ferrule 1x0.2...3.3 mm²
Flexible with Ferrule 2x0.2...1.5 mm²
Solid 1x0.2...3.3 mm²
Solid 2x0.2...1.5 mm²
0.7 N·m
6.5 mm
M3.5
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
IS0 13849
Technical UL/CSA
Crimped Pin 1x 24-12 AWG
Crimped Pin 2x 24-16 AWG
Flexible with Ferrule 1x 24-12 AWG
Flexible with Ferrule 2x 24-16 AWG
Solid 1x 24-12 AWG
Solid 2x 24-16 AWG
Crimped Pin 1x 24-12 AWG
Crimped Pin 2x 24-16 AWG
Flexible with Ferrule 1x 24-12 AWG
Flexible with Ferrule 2x 24-16 AWG
Solid 1x 24-12 AWG
Solid 2x 24-16 AWG
Environmental
Operation -25 ... +65 °C
Storage -40 ... +70 °C
Operation -25 ... +65 °C
Storage -40 ... +70 °C
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Certificates and Declarations
Container Information
box 1 piece
125 mm
31 mm
129 mm
0.268 kg
7350024483338
36 piece
280 mm
395 mm
210 mm
9.9 kg
External Classifications and Standards
K
EC001449 - Device for monitoring of safety-related circuits
EC001449 - Device for monitoring of safety-related circuits
EC001449 - Device for monitoring of safety-related circuits
V11.0 : 27371819
39122331
2712527
3860824

Ordering
7350024483321
1 piece
85364900
Popular Downloads
Dimensions
22.5 mm
120 mm
120 mm
0.207 kg
Technical
Safety relay for monitoring of safety devices
Start/test input, Manual/Auto reset selectable by switch
OFF-Delay
0.5 second
24 V DC
3 A
3 A
IP20
Crimped Pin 1x0.2...3.3 mm²
Crimped Pin 2x0.2...1.5 mm²
Flexible with Ferrule 1x0.2...3.3 mm²
Flexible with Ferrule 2x0.2...1.5 mm²
Solid 1x0.2...3.3 mm²
Solid 2x0.2...1.5 mm²
Crimped Pin 1x0.2...3.3 mm²
Crimped Pin 2x0.2...1.5 mm²
Flexible with Ferrule 1x0.2...3.3 mm²
Flexible with Ferrule 2x0.2...1.5 mm²
Solid 1x0.2...3.3 mm²
Solid 2x0.2...1.5 mm²
0.7 N·m
6.5 mm
M3.5
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
IS0 13849
Technical UL/CSA
Crimped Pin 1x 24-12 AWG
Crimped Pin 2x 24-16 AWG
Flexible with Ferrule 1x 24-12 AWG
Flexible with Ferrule 2x 24-16 AWG
Solid 1x 24-12 AWG
Solid 2x 24-16 AWG
Crimped Pin 1x 24-12 AWG
Crimped Pin 2x 24-16 AWG
Flexible with Ferrule 1x 24-12 AWG
Flexible with Ferrule 2x 24-16 AWG
Solid 1x 24-12 AWG
Solid 2x 24-16 AWG
Environmental
Operation -25 ... +65 °C
Storage -40 ... +70 °C
Operation -25 ... +65 °C
Storage -40 ... +70 °C
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Certificates and Declarations
Container Information
box 1 piece
125 mm
31 mm
129 mm
0.268 kg
7350024483321
36 piece
280 mm
395 mm
210 mm
9.9 kg
External Classifications and Standards
K
EC001449 - Device for monitoring of safety-related circuits
EC001449 - Device for monitoring of safety-related circuits
EC001449 - Device for monitoring of safety-related circuits
V11.0 : 27371819
39122331
2712526
3860823

Ordering
7350024483352
1 piece
85364900
Popular Downloads
Dimensions
22.5 mm
120 mm
120 mm
0.207 kg
Technical
Safety relay for monitoring of safety devices
Start/test input, Auto reset only, Time delay selectable by switch
OFF-Delay
0.5 and 1.5 seconds
24 V DC
5 A
6 A
IP20
Crimped Pin 1x0.2...3.3 mm²
Crimped Pin 2x0.2...1.5 mm²
Flexible with Ferrule 1x0.2...3.3 mm²
Flexible with Ferrule 2x0.2...1.5 mm²
Solid 1x0.2...3.3 mm²
Solid 2x0.2...1.5 mm²
Crimped Pin 1x0.2...3.3 mm²
Crimped Pin 2x0.2...1.5 mm²
Flexible with Ferrule 1x0.2...3.3 mm²
Flexible with Ferrule 2x0.2...1.5 mm²
Solid 1x0.2...3.3 mm²
Solid 2x0.2...1.5 mm²
0.7 N·m
6.5 mm
M3.5
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
IS0 13849
Technical UL/CSA
Crimped Pin 1x 24-12 AWG
Crimped Pin 2x 24-16 AWG
Flexible with Ferrule 1x 24-12 AWG
Flexible with Ferrule 2x 24-16 AWG
Solid 1x 24-12 AWG
Solid 2x 24-16 AWG
Crimped Pin 1x 24-12 AWG
Crimped Pin 2x 24-16 AWG
Flexible with Ferrule 1x 24-12 AWG
Flexible with Ferrule 2x 24-16 AWG
Solid 1x 24-12 AWG
Solid 2x 24-16 AWG
Environmental
Operation -25 ... +65 °C
Storage -40 ... +70 °C
Operation -25 ... +65 °C
Storage -40 ... +70 °C
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Certificates and Declarations
Container Information
box 1 piece
125 mm
31 mm
129 mm
0.268 kg
7350024483352
36 piece
280 mm
395 mm
210 mm
9.9 kg
External Classifications and Standards
K
EC001449 - Device for monitoring of safety-related circuits
EC001449 - Device for monitoring of safety-related circuits
EC001449 - Device for monitoring of safety-related circuits
V11.0 : 27371819
39122331
2712529
3860826

Ordering
7350024483376
1 piece
85364900
Popular Downloads
Dimensions
22.5 mm
120 mm
120 mm
0.229 kg
Technical
Safety relay for monitoring of safety devices
Start/test input, configurable Manual/Auto reset and Timer, Display (error indication and error log)
Multifunction
0 ... 999 seconds
24 V DC
5 A
6 A
IP20
Crimped Pin 1x0.2...3.3 mm²
Crimped Pin 2x0.2...1.5 mm²
Flexible with Ferrule 1x0.2...3.3 mm²
Flexible with Ferrule 2x0.2...1.5 mm²
Solid 1x0.2...3.3 mm²
Solid 2x0.2...1.5 mm²
Crimped Pin 1x0.2...3.3 mm²
Crimped Pin 2x0.2...1.5 mm²
Flexible with Ferrule 1x0.2...3.3 mm²
Flexible with Ferrule 2x0.2...1.5 mm²
Solid 1x0.2...3.3 mm²
Solid 2x0.2...1.5 mm²
0.7 N·m
6.5 mm
M3.5
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
IS0 13849
Technical UL/CSA
Crimped Pin 1x 24-12 AWG
Crimped Pin 2x 24-16 AWG
Flexible with Ferrule 1x 24-12 AWG
Flexible with Ferrule 2x 24-16 AWG
Solid 1x 24-12 AWG
Solid 2x 24-16 AWG
Crimped Pin 1x 24-12 AWG
Crimped Pin 2x 24-16 AWG
Flexible with Ferrule 1x 24-12 AWG
Flexible with Ferrule 2x 24-16 AWG
Solid 1x 24-12 AWG
Solid 2x 24-16 AWG
Environmental
Operation -25 ... +65 °C
Storage -40 ... +70 °C
Operation -25 ... +65 °C
Storage -40 ... +70 °C
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Certificates and Declarations
Container Information
box 1 piece
125 mm
31 mm
129 mm
0.29 kg
7350024483376
36 piece
280 mm
395 mm
210 mm
10.7 kg
External Classifications and Standards
K
EC001449 - Device for monitoring of safety-related circuits
EC001449 - Device for monitoring of safety-related circuits
EC001449 - Device for monitoring of safety-related circuits
V11.0 : 27371819
39122331
2712531
3860828

Ordering
7350024483369
1 piece
85364900
Popular Downloads
Dimensions
22.5 mm
120 mm
120 mm
0.214 kg
Technical
Safety relay for monitoring of safety devices
Start/test input, Auto reset only, Time delay selectable by switch
OFF-Delay
0.5 and 1.5 seconds
120 ... 375 V DC
85 ... 265 V AC
120 ... 375 V DC
85 ... 265 V AC
5 A
6 A
IP20
Crimped Pin 1x0.2...3.3 mm²
Crimped Pin 2x0.2...1.5 mm²
Flexible with Ferrule 1x0.2...3.3 mm²
Flexible with Ferrule 2x0.2...1.5 mm²
Solid 1x0.2...3.3 mm²
Solid 2x0.2...1.5 mm²
Crimped Pin 1x0.2...3.3 mm²
Crimped Pin 2x0.2...1.5 mm²
Flexible with Ferrule 1x0.2...3.3 mm²
Flexible with Ferrule 2x0.2...1.5 mm²
Solid 1x0.2...3.3 mm²
Solid 2x0.2...1.5 mm²
0.7 N·m
6.5 mm
M3.5
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
IS0 13849
Technical UL/CSA
Crimped Pin 1x 24-12 AWG
Crimped Pin 2x 24-16 AWG
Flexible with Ferrule 1x 24-12 AWG
Flexible with Ferrule 2x 24-16 AWG
Solid 1x 24-12 AWG
Solid 2x 24-16 AWG
Crimped Pin 1x 24-12 AWG
Crimped Pin 2x 24-16 AWG
Flexible with Ferrule 1x 24-12 AWG
Flexible with Ferrule 2x 24-16 AWG
Solid 1x 24-12 AWG
Solid 2x 24-16 AWG
Environmental
Operation -25 ... +65 °C
Storage -40 ... +70 °C
Operation -25 ... +65 °C
Storage -40 ... +70 °C
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Certificates and Declarations
Container Information
box 1 piece
125 mm
31 mm
129 mm
0.275 kg
7350024483369
36 piece
280 mm
395 mm
210 mm
10.2 kg
External Classifications and Standards
K
EC001449 - Device for monitoring of safety-related circuits
EC001449 - Device for monitoring of safety-related circuits
EC001449 - Device for monitoring of safety-related circuits
V11.0 : 27371819
39122331
2712530
3860827

Ordering
7350024483345
1 piece
85364900
Popular Downloads
Dimensions
22.5 mm
120 mm
120 mm
0.213 kg
Technical
Safety relay for monitoring of safety devices
Start/test input, configurable Manual/Auto reset and Timer, Display (error indication and error log)
Multifunction
0 ... 999 seconds
24 V DC
5 A
6 A
IP20
Crimped Pin 1x0.2...3.3 mm²
Crimped Pin 2x0.2...1.5 mm²
Flexible with Ferrule 1x0.2...3.3 mm²
Flexible with Ferrule 2x0.2...1.5 mm²
Solid 1x0.2...3.3 mm²
Solid 2x0.2...1.5 mm²
Crimped Pin 1x0.2...3.3 mm²
Crimped Pin 2x0.2...1.5 mm²
Flexible with Ferrule 1x0.2...3.3 mm²
Flexible with Ferrule 2x0.2...1.5 mm²
Solid 1x0.2...3.3 mm²
Solid 2x0.2...1.5 mm²
0.7 N·m
6.5 mm
M3.5
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
IS0 13849
Technical UL/CSA
Crimped Pin 1x 24-12 AWG
Crimped Pin 2x 24-16 AWG
Flexible with Ferrule 1x 24-12 AWG
Flexible with Ferrule 2x 24-16 AWG
Solid 1x 24-12 AWG
Solid 2x 24-16 AWG
Crimped Pin 1x 24-12 AWG
Crimped Pin 2x 24-16 AWG
Flexible with Ferrule 1x 24-12 AWG
Flexible with Ferrule 2x 24-16 AWG
Solid 1x 24-12 AWG
Solid 2x 24-16 AWG
Environmental
Operation -25 ... +65 °C
Storage -40 ... +70 °C
Operation -25 ... +65 °C
Storage -40 ... +70 °C
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Certificates and Declarations
Container Information
box 1 piece
125 mm
31 mm
129 mm
0.274 kg
7350024483345
36 piece
280 mm
395 mm
210 mm
10.2 kg
External Classifications and Standards
K
EC001449 - Device for monitoring of safety-related circuits
EC001449 - Device for monitoring of safety-related circuits
EC001449 - Device for monitoring of safety-related circuits
V11.0 : 27371819
39122331
2712528
3860822

Installation
Environmental
IP20
Technical
Electrical
110 ... 230 V AC
230 V AC
3 W
Design
light grey
Dimensions
4.0
72 mm
90 mm
64.5 mm
0.23 kg
Engineering
Ordering
2815536
4544201
1738904
405631005
Material Compliance
Following EU Directive 2011/65/EU
False - does not contain substances > 0.1 mass percentage
20240123
5. Small Equipment (No External Dimension More Than 50 cm)
Business To Consumer
Certificates and Declarations
External Classifications and Standards
EC000794 - Analogue input for bus system
EC000794 - Analogue input for bus system
V11.0 : 27143107
A
DIN EN 50090-2-2: 1996+Corrigendum:1997+A1:2002+A2:2007

Ordering
85371091
PM564-R-AC:AC500,Prog.Logic Controller
No
1 piece
1 piece
piece
Dimensions
0.4 kg
135 mm
74 mm
82 mm
0.5 kg
Technical
Serial
10 kB
128 kB
Flash EPROM
24...230 V
2 A
IP20
Operation 0 ... +60 °C
Storage -40 ... +70 °C
Operation 0 ... +60 °C
Storage -40 ... +70 °C
Additional Information
PM564
Distributed Automation PLCs
Environmental
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)

Ordering
1 piece
85369095
Tina
DYNlink connection accessory
Yes
Popular Downloads
Dimensions
14 mm
35 mm
77 mm
0.04 kg
Technical
Black
24 V DC
24 V DC
Pluto AS-i v2
Pluto A20 v2
Pluto B20 v2
Pluto B22
Pluto B42 AS-i
Pluto B46 v2
Pluto D20
Pluto D45
Pluto D45 (Harsh Env)
Pluto O2
Pluto S20 v2
Pluto S46 v2
Vital 1
B&R X20
Pluto AS-i v2
Pluto A20 v2
Pluto B20 v2
Pluto B22
Pluto B42 AS-i
Pluto B46 v2
Pluto D20
Pluto D45
Pluto D45 (Harsh Env)
Pluto O2
24 V DC
Environmental
Operation -10 ... 55 °C
IP67
Plastic
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
Certificates and Declarations
Container Information
bag 1 piece
60 mm
90 mm
0.015 m
0.042 kg
7350024451986
External Classifications and Standards
V11.0 : 27060313
EC001584 - I/O device for bus system
EC001584 - I/O device for bus system
EC003558 - Passive sensor-actuator interface (without cable)
5219 >> Switch part or accessory
39122221
T
2307394
3860126

Additional Information
This CPU module is the medium base unit of the Freelance AC 900F controller family. Depending on the application, it is sufficient for around 1.500 IOs.
4 Ethernet interfaces, 800 MHz CPU clock,
24 MB Controller Memory, 8 MB battery buffered SRAM, 16 MB DRAM.
2 slots for assembling Communication Interface Modules.
Needs external 24 VDC power supply.
Software version see instruction leaflet 2PAA120973-003.
Display Unit TD 951F and Battery TA 951F are not included.
Central_Unit
Ordering
853710 -- ELECTRICAL MACHINERY AND EQUIPMENT AND PARTS THEREOF; SOUND RECORDERS AND REPRODUCERS, TELEVISION IMAGE AND SOUND RECORDERS AND REPRODUCERS, AND PARTS AND ACCESSORIES OF SUCH ARTICLES;Boards, panels, consoles, desks, cabinets and other bases, equipped with two or more apparatus of heading|8535|or 8536, for electric control or the distribution of electricity, including those incorporating instruments or apparatus of Chapter|90, and numerical control apparatus, other than switching apparatus of heading|8517;For a voltage not exceeding 1|000|V
85371091
Dimensions
95 mm
152 mm
227 mm
1.1 kg
Environmental
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
5. Small Equipment (No External Dimension More Than 50 cm)
0
No SVHC present United States

Additional Information
Including:
- 2 pcs BC810, Interconnection Unit
- 2 pcs TP857, Baseplate
- TK851, Interconnection Cable
- 2 pcs TB850, CEX-Bus Terminator
Communication_Module
Ordering
851762 -- ELECTRICAL MACHINERY AND EQUIPMENT AND PARTS THEREOF; SOUND RECORDERS AND REPRODUCERS, TELEVISION IMAGE AND SOUND RECORDERS AND REPRODUCERS, AND PARTS AND ACCESSORIES OF SUCH ARTICLES;Telephone sets, including smartphones and other telephones for cellular networks or for other wireless networks; other apparatus for the transmission or reception of voice, images or other data, including apparatus for communication in a wired or wireless network (such as a local or wide area network), other than transmission or reception apparatus of heading 8443, 8525, 8527 or 8528;Other apparatus for the transmission or reception of voice, images or other data, including apparatus for communication in a wired or wireless network (such as a local or wide area network);Machines for the reception, conversion and transmission or regeneration of voice, images or other data, including switching and routing apparatus
85176200
Dimensions
127.5 mm
185 mm
59 mm
1.55 kg
Environmental
Following EU Directive 2011/65/EU
5. Small Equipment (No External Dimension More Than 50 cm)
0
6518e801-deaf-4796-9f19-b06356f613ec Sweden

Additional Information
Central_Unit
Ordering
853710 -- ELECTRICAL MACHINERY AND EQUIPMENT AND PARTS THEREOF; SOUND RECORDERS AND REPRODUCERS, TELEVISION IMAGE AND SOUND RECORDERS AND REPRODUCERS, AND PARTS AND ACCESSORIES OF SUCH ARTICLES;Boards, panels, consoles, desks, cabinets and other bases, equipped with two or more apparatus of heading|8535|or 8536, for electric control or the distribution of electricity, including those incorporating instruments or apparatus of Chapter|90, and numerical control apparatus, other than switching apparatus of heading|8517;For a voltage not exceeding 1|000|V
85371091
Dimensions
101.6 mm
254 mm
203.2 mm
0 kg
Environmental
5. Small Equipment (No External Dimension More Than 50 cm)
1
Lithium
Button Cell
5 g
98b11c33-bf0a-4725-a050-02b0fc938049 Malta