Technical

Rated Operational Voltage:
208 ... 690 V AC
Rated Control Supply Voltage (Us):
100 ... 250 V AC
Rated Control Circuit Voltage (Uc):
24 V DC
Rated Frequency (f):
50/60 Hz
Main Circuit 50 / 60 Hz
50/60 Hz
Main Circuit 50 / 60 Hz
Rated Operational Power - In-Line Connection (Pe):
(230 V) 400 kW
(400 V) 710 kW
(500 V) 880 kW
(690 V) 1200 kW
(230 V) 400 kW
(400 V) 710 kW
(500 V) 880 kW
(690 V) 1200 kW
Rated Operational Current - In-Line Connection (Ie):
1250 A
Rated Operational Power - Inside Delta Connection:
at 230 V 670 kW
at 400 V 1200 kW
at 500 V 1500 kW
at 690 V 2000 kW
at 230 V 670 kW
at 400 V 1200 kW
at 500 V 1500 kW
at 690 V 2000 kW
Rated Operational Current - Inside Delta Connection:
2160 A
Service Factor Percentage:
100 %
Overload Protection:
Built-in electronic overload protection
Integrated Electronic Overload:
Yes
Starting Capacity at Maximum Rated Current Ie:
4xIe for 10s
Ramp Time:
1 ... 120 second [unit of time]
Initial Voltage During Start:
10 ... 99 A
Step Down Voltage Special Ramp:
100 ... 10 %
Current Limit Function:
1.5 ... 7.5 xle
Switch for Inside Delta Connection:
Yes
Run Signal Relay:
Yes
By-pass Signal Relay:
Yes
Fault Signal Relay:
Yes
Overload Signal Relay:
Yes
Analog Outputs:
0…10 V, 0…20 mA, 4…20 mA
Signal Indication Ready to Start/Standby ON (LED):
Green
Signal Indication Running R (LED):
Green
Signal Indication Protection (LED):
Yellow
Signal Indication Fault (LED):
Red
Communication:
Modbus-RTU; Modbus-TCP; Ethernet-IP; EtherCAT; DeviceNet; CANopen; Profibus; Profinet; BACnet-IP; BACnet-MSTP
Degree of Protection:
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Terminal Type:
Main Circuit: Bars
Connecting Capacity Control Circuit:
Rigid 1 x 2.5 mm²
Connecting Capacity Supply Circuit:
Rigid 1 x 2.5
Tightening Torque:
Main Circuit 45 N·m
Product Main Type:
PSTX1250
Function:
Auto phase sequence detection
Automatic restart
Current limit
Current limit ramp
Dual current limit
Dynamic brake
Electricity metering
Electronic overload Time-to-cool
Emergency mode
Event log
Full voltage start
Jog with slow speed, forward and reverse
Keypad password
Kick start
Limp mode with two-phase motor control if one set of thyristors is shorted
Motor heating
Pre-start function
Pump cleaning
Real time clock
Sequence start
Soft start with torque control
Soft start with voltage ramp
Soft stop with torque control
Soft stop with voltage ramp
Stand still brake
Start reverse (external contactors)
Thyristor runtime measurement
Torque limit
Voltage sags detection
Auto phase sequence detection
Automatic restart
Current limit
Current limit ramp
Dual current limit
Dynamic brake
Electricity metering
Electronic overload Time-to-cool
Emergency mode
Event log
Protection Function:
Bypass open protection; Current imbalance protection; Current underload protection; Dual overload (separate overload for start and run); Earth fault protection / ground fault protection; Electronic overload protection, EOL; Extension IO failure protection; Fieldbus failure protection; HMI failure protection; Locked rotor protection; Max number of starts/hour; Over voltage protection; Phase reversal protection; Power factor underload protection; PT-100 connection; PTC connection; Too long current limit protection; Too long start time protection; Under voltage protection; User defined protection; Voltage imbalance protection
Warning Details:
Current imbalance warning; Current underload warning; Electronic overload Time-to-trip; EOL warning; Faulty fan warning; Locked rotor warning; Motor runtime limit warning; Over voltage warning; Phase loss warning (for standby); Power factor underload warning; Short circuit warning (for Limp mode); THD(U) - Total Harmonic Distortion warning; Thyristor overload warning (SCR); Under voltage warning; Voltage imbalance warning

Technical UL/CSA

Horsepower Rating UL/CSA:
(200 ... 208 V AC) Three Phase 400 Hp
(220 ... 240 V AC) Three Phase 500 Hp
(440 ... 480 V AC) Three Phase 1000 Hp
(550 ... 600 V AC) Three Phase 1200 Hp
(200 ... 208 V AC) Three Phase 400 Hp
(220 ... 240 V AC) Three Phase 500 Hp
(440 ... 480 V AC) Three Phase 1000 Hp
(550 ... 600 V AC) Three Phase 1200 Hp
Maximum Operating Voltage UL/CSA:
Main Circuit 690 V
Tightening Torque UL/CSA:
Main Circuit 398.3

Environmental

Ambient Air Temperature:
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Operation -25 ... +60 °C
Storage -40 ... +70 °C

Material Compliance

Conflict Minerals Reporting Template (CMRT):
RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
WEEE B2C / B2B:
Business To Business
WEEE Category:
4. Large Equipment (Any External Dimension More Than 50 cm)

Certificates and Declarations

Container Information

Package Level 1 Width:
600 mm
Package Level 1 Depth / Length:
616 mm
Package Level 1 Height:
800 mm
Package Level 1 Gross Weight:
75.3 kg
Package Level 1 EAN:
7320500510483
Package Level 1 Units:
box 1 piece

External Classifications and Standards

Object Classification Code:
Q
ETIM 7:
EC000640 - Soft starter
ETIM 8:
EC000640 - Soft starter
ETIM 9:
EC000640 - Soft starter
eClass:
V11.0 : 27370907
UNSPSC:
39121521
IDEA Granular Category Code (IGCC):
4740 >> Soft starter

Sale price€10.965,95
1-year warranty
FREE WORDWIDE SHIPPING
Est. delivery between and  
Estimated delivery dates are estimates only. Int'l customers allow a few more days. For more precise delivery estimates, please contact us at support@plc-direct.com. Contact us in advance for expedited shipping options.
Condition:
€10.965,95
€0,00
€0,00

Ach Direct Debit American Express Apple Pay Diners Club Discover Google Pay Mastercard PayPal Shop Pay Visa
Description
Warranty
Shipping and Return

Ordering

Minimum Order Quantity:
1 piece
Customs Tariff Number:
85371091

Popular Downloads

Data Sheet, Technical Information:
Instructions and Manuals:
Instructions and Manuals (Part 2):
Instructions and Manuals (Part 3):
EPLAN Data:
Wiring Diagram:

Dimensions

Product Net Width:
435 mm
Product Net Height:
565 mm
Product Net Depth / Length:
367 mm
Product Net Weight:
63.3 kg

Technical

Rated Operational Voltage:
208 ... 690 V AC
Rated Control Supply Voltage (Us):
100 ... 250 V AC
Rated Control Circuit Voltage (Uc):
24 V DC
Rated Frequency (f):
50/60 Hz
Main Circuit 50 / 60 Hz
50/60 Hz
Main Circuit 50 / 60 Hz
Rated Operational Power - In-Line Connection (Pe):
(230 V) 400 kW
(400 V) 710 kW
(500 V) 880 kW
(690 V) 1200 kW
(230 V) 400 kW
(400 V) 710 kW
(500 V) 880 kW
(690 V) 1200 kW
Rated Operational Current - In-Line Connection (Ie):
1250 A
Rated Operational Power - Inside Delta Connection:
at 230 V 670 kW
at 400 V 1200 kW
at 500 V 1500 kW
at 690 V 2000 kW
at 230 V 670 kW
at 400 V 1200 kW
at 500 V 1500 kW
at 690 V 2000 kW
Rated Operational Current - Inside Delta Connection:
2160 A
Service Factor Percentage:
100 %
Overload Protection:
Built-in electronic overload protection
Integrated Electronic Overload:
Yes
Starting Capacity at Maximum Rated Current Ie:
4xIe for 10s
Ramp Time:
1 ... 120 second [unit of time]
Initial Voltage During Start:
10 ... 99 A
Step Down Voltage Special Ramp:
100 ... 10 %
Current Limit Function:
1.5 ... 7.5 xle
Switch for Inside Delta Connection:
Yes
Run Signal Relay:
Yes
By-pass Signal Relay:
Yes
Fault Signal Relay:
Yes
Overload Signal Relay:
Yes
Analog Outputs:
0…10 V, 0…20 mA, 4…20 mA
Signal Indication Ready to Start/Standby ON (LED):
Green
Signal Indication Running R (LED):
Green
Signal Indication Protection (LED):
Yellow
Signal Indication Fault (LED):
Red
Communication:
Modbus-RTU; Modbus-TCP; Ethernet-IP; EtherCAT; DeviceNet; CANopen; Profibus; Profinet; BACnet-IP; BACnet-MSTP
Degree of Protection:
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Terminal Type:
Main Circuit: Bars
Connecting Capacity Control Circuit:
Rigid 1 x 2.5 mm²
Connecting Capacity Supply Circuit:
Rigid 1 x 2.5
Tightening Torque:
Main Circuit 45 N·m
Product Main Type:
PSTX1250
Function:
Auto phase sequence detection
Automatic restart
Current limit
Current limit ramp
Dual current limit
Dynamic brake
Electricity metering
Electronic overload Time-to-cool
Emergency mode
Event log
Full voltage start
Jog with slow speed, forward and reverse
Keypad password
Kick start
Limp mode with two-phase motor control if one set of thyristors is shorted
Motor heating
Pre-start function
Pump cleaning
Real time clock
Sequence start
Soft start with torque control
Soft start with voltage ramp
Soft stop with torque control
Soft stop with voltage ramp
Stand still brake
Start reverse (external contactors)
Thyristor runtime measurement
Torque limit
Voltage sags detection
Auto phase sequence detection
Automatic restart
Current limit
Current limit ramp
Dual current limit
Dynamic brake
Electricity metering
Electronic overload Time-to-cool
Emergency mode
Event log
Protection Function:
Bypass open protection; Current imbalance protection; Current underload protection; Dual overload (separate overload for start and run); Earth fault protection / ground fault protection; Electronic overload protection, EOL; Extension IO failure protection; Fieldbus failure protection; HMI failure protection; Locked rotor protection; Max number of starts/hour; Over voltage protection; Phase reversal protection; Power factor underload protection; PT-100 connection; PTC connection; Too long current limit protection; Too long start time protection; Under voltage protection; User defined protection; Voltage imbalance protection
Warning Details:
Current imbalance warning; Current underload warning; Electronic overload Time-to-trip; EOL warning; Faulty fan warning; Locked rotor warning; Motor runtime limit warning; Over voltage warning; Phase loss warning (for standby); Power factor underload warning; Short circuit warning (for Limp mode); THD(U) - Total Harmonic Distortion warning; Thyristor overload warning (SCR); Under voltage warning; Voltage imbalance warning

Technical UL/CSA

Horsepower Rating UL/CSA:
(200 ... 208 V AC) Three Phase 400 Hp
(220 ... 240 V AC) Three Phase 500 Hp
(440 ... 480 V AC) Three Phase 1000 Hp
(550 ... 600 V AC) Three Phase 1200 Hp
(200 ... 208 V AC) Three Phase 400 Hp
(220 ... 240 V AC) Three Phase 500 Hp
(440 ... 480 V AC) Three Phase 1000 Hp
(550 ... 600 V AC) Three Phase 1200 Hp
Maximum Operating Voltage UL/CSA:
Main Circuit 690 V
Tightening Torque UL/CSA:
Main Circuit 398.3

Environmental

Ambient Air Temperature:
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Operation -25 ... +60 °C
Storage -40 ... +70 °C

Material Compliance

Conflict Minerals Reporting Template (CMRT):
RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
WEEE B2C / B2B:
Business To Business
WEEE Category:
4. Large Equipment (Any External Dimension More Than 50 cm)

Certificates and Declarations

Container Information

Package Level 1 Width:
600 mm
Package Level 1 Depth / Length:
616 mm
Package Level 1 Height:
800 mm
Package Level 1 Gross Weight:
75.3 kg
Package Level 1 EAN:
7320500510483
Package Level 1 Units:
box 1 piece

External Classifications and Standards

Object Classification Code:
Q
ETIM 7:
EC000640 - Soft starter
ETIM 8:
EC000640 - Soft starter
ETIM 9:
EC000640 - Soft starter
eClass:
V11.0 : 27370907
UNSPSC:
39121521
IDEA Granular Category Code (IGCC):
4740 >> Soft starter

All PLC Direct products come with a 1-year warranty. The warranty is issued by PLC Direct. Warranty coverage commences at the date of purchase. The warranty is for mechanical defects or failures not caused by human factors including but not limited to (a) incorrect installation, (b) operating the unit in sub-optimal conditions or in scenarios not recommended by the manufacturer, (c) poor unit maintenance, etc. The warranty does not cover programming or software related issues.

If the product is eligible for PLC Direct’s warranty coverage and the customer encounters an issue with the product, we will request the item is shipped to us for diagnosis and examination. Regardless of the cause of product issues, the customer will bear responsibility for the cost of shipping the unit to PLC Direct for evaluation. Where the unit was damaged by human factors, we will offer a repair or replace quote; in cases where damage was caused by human factors, the customer is responsible for the cost of shipping the repaired/replaced unit from PLC Direct to the customer. Where the unit was not damaged by human factors but is covered by PLC Direct’s warranty, we will repair or replace the unit at our cost (or, in rare cases, refund you your purchase); in such cases, PLC Direct will bear the cost of shipping the repaired or replaced product back to the customer. It is up to PLC Direct’s discretion whether to repair, replace, or refund the customer in such cases. Diagnoses can take time to complete based on technician availability and the complexity of diagnosis.

In no event shall PLC Direct be liable for any damages except actual damages up to, but not exceeding, the amount paid to us for the product, including we shall not be liable for any consequential or indirect damages or lost profits whether or not advised of same.

PLC Direct offers free shipping worldwide. Product ship from a various warehouses worldwide based on the customer's and the product's location. The estimated delivery date on the product page is PLC Direct's best estimated assuming a US-based shipping destination.

Regardless of where the product is shipping from, PLC Direct covers all duties for US-based shipping destinations. For non-US-based shipping destinations, customers are responsible for duties as appropriate.

PLC Direct's focus is on balancing price with lead time. Some but not all products can be expedited. If you have questions about delivery ETAs, please contact our team.

Description
Warranty
Shipping and Return

Ordering

Minimum Order Quantity:
1 piece
Customs Tariff Number:
85371091

Popular Downloads

Data Sheet, Technical Information:
Instructions and Manuals:
Instructions and Manuals (Part 2):
Instructions and Manuals (Part 3):
EPLAN Data:
Wiring Diagram:

Dimensions

Product Net Width:
435 mm
Product Net Height:
565 mm
Product Net Depth / Length:
367 mm
Product Net Weight:
63.3 kg

Technical

Rated Operational Voltage:
208 ... 690 V AC
Rated Control Supply Voltage (Us):
100 ... 250 V AC
Rated Control Circuit Voltage (Uc):
24 V DC
Rated Frequency (f):
50/60 Hz
Main Circuit 50 / 60 Hz
50/60 Hz
Main Circuit 50 / 60 Hz
Rated Operational Power - In-Line Connection (Pe):
(230 V) 400 kW
(400 V) 710 kW
(500 V) 880 kW
(690 V) 1200 kW
(230 V) 400 kW
(400 V) 710 kW
(500 V) 880 kW
(690 V) 1200 kW
Rated Operational Current - In-Line Connection (Ie):
1250 A
Rated Operational Power - Inside Delta Connection:
at 230 V 670 kW
at 400 V 1200 kW
at 500 V 1500 kW
at 690 V 2000 kW
at 230 V 670 kW
at 400 V 1200 kW
at 500 V 1500 kW
at 690 V 2000 kW
Rated Operational Current - Inside Delta Connection:
2160 A
Service Factor Percentage:
100 %
Overload Protection:
Built-in electronic overload protection
Integrated Electronic Overload:
Yes
Starting Capacity at Maximum Rated Current Ie:
4xIe for 10s
Ramp Time:
1 ... 120 second [unit of time]
Initial Voltage During Start:
10 ... 99 A
Step Down Voltage Special Ramp:
100 ... 10 %
Current Limit Function:
1.5 ... 7.5 xle
Switch for Inside Delta Connection:
Yes
Run Signal Relay:
Yes
By-pass Signal Relay:
Yes
Fault Signal Relay:
Yes
Overload Signal Relay:
Yes
Analog Outputs:
0…10 V, 0…20 mA, 4…20 mA
Signal Indication Ready to Start/Standby ON (LED):
Green
Signal Indication Running R (LED):
Green
Signal Indication Protection (LED):
Yellow
Signal Indication Fault (LED):
Red
Communication:
Modbus-RTU; Modbus-TCP; Ethernet-IP; EtherCAT; DeviceNet; CANopen; Profibus; Profinet; BACnet-IP; BACnet-MSTP
Degree of Protection:
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Terminal Type:
Main Circuit: Bars
Connecting Capacity Control Circuit:
Rigid 1 x 2.5 mm²
Connecting Capacity Supply Circuit:
Rigid 1 x 2.5
Tightening Torque:
Main Circuit 45 N·m
Product Main Type:
PSTX1250
Function:
Auto phase sequence detection
Automatic restart
Current limit
Current limit ramp
Dual current limit
Dynamic brake
Electricity metering
Electronic overload Time-to-cool
Emergency mode
Event log
Full voltage start
Jog with slow speed, forward and reverse
Keypad password
Kick start
Limp mode with two-phase motor control if one set of thyristors is shorted
Motor heating
Pre-start function
Pump cleaning
Real time clock
Sequence start
Soft start with torque control
Soft start with voltage ramp
Soft stop with torque control
Soft stop with voltage ramp
Stand still brake
Start reverse (external contactors)
Thyristor runtime measurement
Torque limit
Voltage sags detection
Auto phase sequence detection
Automatic restart
Current limit
Current limit ramp
Dual current limit
Dynamic brake
Electricity metering
Electronic overload Time-to-cool
Emergency mode
Event log
Protection Function:
Bypass open protection; Current imbalance protection; Current underload protection; Dual overload (separate overload for start and run); Earth fault protection / ground fault protection; Electronic overload protection, EOL; Extension IO failure protection; Fieldbus failure protection; HMI failure protection; Locked rotor protection; Max number of starts/hour; Over voltage protection; Phase reversal protection; Power factor underload protection; PT-100 connection; PTC connection; Too long current limit protection; Too long start time protection; Under voltage protection; User defined protection; Voltage imbalance protection
Warning Details:
Current imbalance warning; Current underload warning; Electronic overload Time-to-trip; EOL warning; Faulty fan warning; Locked rotor warning; Motor runtime limit warning; Over voltage warning; Phase loss warning (for standby); Power factor underload warning; Short circuit warning (for Limp mode); THD(U) - Total Harmonic Distortion warning; Thyristor overload warning (SCR); Under voltage warning; Voltage imbalance warning

Technical UL/CSA

Horsepower Rating UL/CSA:
(200 ... 208 V AC) Three Phase 400 Hp
(220 ... 240 V AC) Three Phase 500 Hp
(440 ... 480 V AC) Three Phase 1000 Hp
(550 ... 600 V AC) Three Phase 1200 Hp
(200 ... 208 V AC) Three Phase 400 Hp
(220 ... 240 V AC) Three Phase 500 Hp
(440 ... 480 V AC) Three Phase 1000 Hp
(550 ... 600 V AC) Three Phase 1200 Hp
Maximum Operating Voltage UL/CSA:
Main Circuit 690 V
Tightening Torque UL/CSA:
Main Circuit 398.3

Environmental

Ambient Air Temperature:
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Operation -25 ... +60 °C
Storage -40 ... +70 °C

Material Compliance

Conflict Minerals Reporting Template (CMRT):
RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
WEEE B2C / B2B:
Business To Business
WEEE Category:
4. Large Equipment (Any External Dimension More Than 50 cm)

Certificates and Declarations

Container Information

Package Level 1 Width:
600 mm
Package Level 1 Depth / Length:
616 mm
Package Level 1 Height:
800 mm
Package Level 1 Gross Weight:
75.3 kg
Package Level 1 EAN:
7320500510483
Package Level 1 Units:
box 1 piece

External Classifications and Standards

Object Classification Code:
Q
ETIM 7:
EC000640 - Soft starter
ETIM 8:
EC000640 - Soft starter
ETIM 9:
EC000640 - Soft starter
eClass:
V11.0 : 27370907
UNSPSC:
39121521
IDEA Granular Category Code (IGCC):
4740 >> Soft starter

All PLC Direct products come with a 1-year warranty. The warranty is issued by PLC Direct. Warranty coverage commences at the date of purchase. The warranty is for mechanical defects or failures not caused by human factors including but not limited to (a) incorrect installation, (b) operating the unit in sub-optimal conditions or in scenarios not recommended by the manufacturer, (c) poor unit maintenance, etc. The warranty does not cover programming or software related issues.

If the product is eligible for PLC Direct’s warranty coverage and the customer encounters an issue with the product, we will request the item is shipped to us for diagnosis and examination. Regardless of the cause of product issues, the customer will bear responsibility for the cost of shipping the unit to PLC Direct for evaluation. Where the unit was damaged by human factors, we will offer a repair or replace quote; in cases where damage was caused by human factors, the customer is responsible for the cost of shipping the repaired/replaced unit from PLC Direct to the customer. Where the unit was not damaged by human factors but is covered by PLC Direct’s warranty, we will repair or replace the unit at our cost (or, in rare cases, refund you your purchase); in such cases, PLC Direct will bear the cost of shipping the repaired or replaced product back to the customer. It is up to PLC Direct’s discretion whether to repair, replace, or refund the customer in such cases. Diagnoses can take time to complete based on technician availability and the complexity of diagnosis.

In no event shall PLC Direct be liable for any damages except actual damages up to, but not exceeding, the amount paid to us for the product, including we shall not be liable for any consequential or indirect damages or lost profits whether or not advised of same.

PLC Direct offers free shipping worldwide. Product ship from a various warehouses worldwide based on the customer's and the product's location. The estimated delivery date on the product page is PLC Direct's best estimated assuming a US-based shipping destination.

Regardless of where the product is shipping from, PLC Direct covers all duties for US-based shipping destinations. For non-US-based shipping destinations, customers are responsible for duties as appropriate.

PLC Direct's focus is on balancing price with lead time. Some but not all products can be expedited. If you have questions about delivery ETAs, please contact our team.

Trusted By

"Fast service for obsolete parts"

Increasingly PLC/ HMI control platforms are becoming obsolete and parts are no longer supported, however PLC Direct had the HMI we needed and fast shipping for our system to get back online!

Buyer at GE Health

"Helping us move projects forward"

With supply chain issues increasingly affecting our business, PLC Direct has been there for us to supply the PLC products we need, when we need it. If they don't have it readily available, they find it and provide it quickly and reliably. This has helped us move forward with several projects that would have otherwise taken us many, many months to complete.

Buyer at E-Merge Systems – A Rockwell Integrator

You may also like

Recently viewed