
Ordering
Popular Downloads
Dimensions
111.5 mm
160 mm
196 mm
2.9 kg
Technical
3
0
1
1
3P
Main Circuit 690 V
Main Circuit 50 / 60 Hz
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 250 A
(1000 V) 40 °C 180 A
(1000 V) 55 °C 180 A
(1000 V) 70 °C 180 A
(690 V) 40 °C 250 A
(690 V) 55 °C 230 A
(690 V) 70 °C 180 A
(1000 V) 40 °C 180 A
(1000 V) 55 °C 180 A
(1000 V) 70 °C 180 A
(690 V) 40 °C 250 A
(690 V) 55 °C 230 A
(690 V) 70 °C 180 A
(415 V) 55 °C 145 A
(440 V) 55 °C 145 A
(500 V) 55 °C 145 A
(690 V) 55 °C 120 A
(1000 V) 55 °C 80 A
(380 / 400 V) 55 °C 145 A
(220 / 230 / 240 V) 55 °C 145
(415 V) 55 °C 145 A
(440 V) 55 °C 145 A
(500 V) 55 °C 145 A
(690 V) 55 °C 120 A
(1000 V) 55 °C 80 A
(380 / 400 V) 55 °C 145 A
(220 / 230 / 240 V) 55 °C 145
(110 V) 2 Poles in Series, 40 °C 250 A
(220 V) 3 Poles in Series, 40 °C 250 A
(110 V) 2 Poles in Series, 40 °C 250 A
(220 V) 3 Poles in Series, 40 °C 250 A
(110 V) 2 Poles in Series, 40 °C 250 A
(220 V) 3 Poles in Series, 40 °C 250 A
(110 V) 2 Poles in Series, 40 °C 250 A
(220 V) 3 Poles in Series, 40 °C 250 A
(110 V) 2 Poles in Series, 40 °C 250 A
(220 V) 3 Poles in Series, 40 °C 250 A
(110 V) 2 Poles in Series, 40 °C 250 A
(220 V) 3 Poles in Series, 40 °C 250 A
(415 V) 75 kW
(440 V) 75 kW
(500 V) 90 kW
(690 V) 110 kW
(380 / 400 V) 75 kW
(220 / 230 / 240 V) 45 kW
(415 V) 75 kW
(440 V) 75 kW
(500 V) 90 kW
(690 V) 110 kW
(380 / 400 V) 75 kW
(220 / 230 / 240 V) 45 kW
8 x Ie AC-3
10 x Ie AC-3
gG Type Fuses 315 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 1200 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 280 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 600 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1800 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 800 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 1200 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 280 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 600 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1800 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 800 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1500 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 1200 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1500 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 1200 A
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
acc. to UL/CSA 600 V
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
acc. to UL/CSA 600 V
Main Circuit 8 kV
(AC-1) 300 cycles per hour
(AC-2 / AC-4) 150 cycles per hour
(AC-3) 300 cycles per hour
(AC-1) 300 cycles per hour
(AC-2 / AC-4) 150 cycles per hour
(AC-3) 300 cycles per hour
5 million
3600 cycles per hour
(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
50 Hz 110 V
60 Hz 110 ... 120 V
50 Hz 110 V
60 Hz 110 ... 120 V
Holding at Max. Rated Control Circuit Voltage 50 Hz 35 V·A
Holding at Max. Rated Control Circuit Voltage 60 Hz 40 V·A
Pull-in at Max. Rated Control Circuit Voltage 50 Hz 550 V·A
Pull-in at Max. Rated Control Circuit Voltage 60 Hz 600 V·A
Holding at Max. Rated Control Circuit Voltage 50 Hz 35 V·A
Holding at Max. Rated Control Circuit Voltage 60 Hz 40 V·A
Pull-in at Max. Rated Control Circuit Voltage 50 Hz 550 V·A
Pull-in at Max. Rated Control Circuit Voltage 60 Hz 600 V·A
at Rated Operating Conditions per Pole 5 W
Between Coil De-energization and NC Contact Closing 5 ... 10 ms
Between Coil De-energization and NO Contact Opening 9 ... 13 ms
Between Coil Energization and NC Contact Opening 8 ... 22 ms
Between Coil Energization and NO Contact Closing 13 ... 27 ms
Between Coil De-energization and NC Contact Closing 5 ... 10 ms
Between Coil De-energization and NO Contact Opening 9 ... 13 ms
Between Coil Energization and NC Contact Opening 8 ... 22 ms
Between Coil Energization and NO Contact Closing 13 ... 27 ms
Bar 24 mm²
Rigid Al-Cable 1 x 25 ... 150 mm²
Rigid Cu-Cable 1 x 6 ... 185 mm²
Bar 24 mm²
Rigid Al-Cable 1 x 25 ... 150 mm²
Rigid Cu-Cable 1 x 6 ... 185 mm²
Flexible with Ferrule 2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm²
Flexible 2x0.75 ... 2.5 mm²
Solid 1 x 1 ... 4 mm²
Stranded 2 x 1 .... 4 mm²
Flexible with Ferrule 2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm²
Flexible 2x0.75 ... 2.5 mm²
Solid 1 x 1 ... 4 mm²
Stranded 2 x 1 .... 4 mm²
Bar 24 mm²
Rigid Al-Cable 1 x 25 ... 150 mm²
Rigid Cu-Cable 1 x 6 ... 185 mm²
Bar 24 mm²
Rigid Al-Cable 1 x 25 ... 150 mm²
Rigid Cu-Cable 1 x 6 ... 185 mm²
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Flat type c/w screws and bolts
Main Circuit 18 N·m
Main Circuit: Bars
Block Contactor
Technical UL/CSA
4
Main Circuit 600 V
(600 V AC) 230 A
(200 V AC) Three Phase 40 hp
(208 V AC) Three Phase 40 hp
(220 ... 240 V AC) Three Phase 50 hp
(440 ... 480 V AC) Three Phase 100 hp
(550 ... 600 V AC) Three Phase 125 hp
(200 V AC) Three Phase 40 hp
(208 V AC) Three Phase 40 hp
(220 ... 240 V AC) Three Phase 50 hp
(440 ... 480 V AC) Three Phase 100 hp
(550 ... 600 V AC) Three Phase 125 hp
(440 ... 480 V AC) Three Phase 124 A
(550 ... 600 V AC) Three Phase 125 A
(440 ... 480 V AC) Three Phase 124 A
(550 ... 600 V AC) Three Phase 125 A
Environmental
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C
Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C
Close to Contactor for Storage -40 ... 70 °C
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C
Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C
Close to Contactor for Storage -40 ... 70 °C
Without Derating 3000 m
Shock Direction: A 5 g
Shock Direction: B1 5 g
Shock Direction: B2 5 g
Shock Direction: C1 5 g
Shock Direction: C2 5 g
Shock Direction: A 5 g
Shock Direction: B1 5 g
Shock Direction: B2 5 g
Shock Direction: C1 5 g
Shock Direction: C2 5 g
Material Compliance
Following EU Directive 2011/65/EU
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
Certificates and Declarations
Container Information
box 1 piece
178 mm
232 mm
167 mm
3.5 kg
7320500203293
External Classifications and Standards
Q
EC000066 - Power contactor, AC switching
EC000066 - Power contactor, AC switching
EC000066 - Power contactor, AC switching
V11.0 : 27371003
39121529
4755 >> Contactors
3709243
4115094
3227853

Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Ordering
ZEAEKPTP
3182072
8015644008956
1 piece
85389099
Dimensions
225 mm
150 mm
345 mm
0.999 kg
Container Information
1 piece
225 mm
150 mm
345 mm
1.052 kg
8015644008956
Additional Information
Accessories for Emax 2, Accessories for Tmax XT
Accessory
Accessory
E1.2
E2.2
E4.2
E6.2
XT2
XT4
XT5
XT7
XT7M
E1.2
E2.2
E4.2
E6.2
XT2
XT4
XT5
XT7
XT7M
SACE Emax 2
Technical
Loose or configurable
1 piece
IEC
Certificates and Declarations
External Classifications and Standards
EC002498 - Accessories/spare parts for low-voltage switch technology
EC002498 - Accessories/spare parts for low-voltage switch technology
5219 >> Switch part or accessory
Q
39122221
5. Small Equipment (No External Dimension More Than 50 cm)
V11.1 : 27371392

Material Compliance
Environmental
Ordering
4377316
8015644517915
1 piece
85389099
Dimensions
0.04 kg
Container Information
1 piece
110 mm
60 mm
140 mm
0.06 kg
8015644517915
Additional Information
Accessories for Tmax T
Accessory
ACC
T1, T2, T3
SACE Tmax T
Technical
Loose or configurable
T1-T2-T3
IEC
Certificates and Declarations
External Classifications and Standards
Q
39120000
5. Small Equipment (No External Dimension More Than 50 cm)

ABB EcoSolutions
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Environmental
Ordering
KT5VD
3655661
4383645
8015644560515
1 piece
85362090
Dimensions
0.724 kg
Container Information
1 piece
125 mm
120 mm
485 mm
0.762 kg
8015644560515
Additional Information
Accessories for Tmax T
Accessory
Accessory
T4, T5
SACE Tmax T
Technical
Loose or configurable
7,275 cm³
IEC
Certificates and Declarations
External Classifications and Standards
EC000229 - Handle for power circuit breaker
EC000229 - Handle for power circuit breaker
3038 >> Handles or knobs
Q
31162801
4. Large Equipment (Any External Dimension More Than 50 cm)
V11.1 : 27370414

Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Environmental
Ordering
KXT5RHESTFP
3642199
4381188
8015644069353
1 piece
85389099
Dimensions
0.444 kg
Container Information
box 1 piece
125 mm
120 mm
485 mm
0.467 kg
8015644069353
Additional Information
Accessories for Tmax XT
Accessory
Accessory
XT5
SACE Tamx XT
Technical
Loose or configurable
1 piece
IEC60947-2
UL489
IEC60947-2
UL489
Certificates and Declarations
External Classifications and Standards
EC000229 - Handle for power circuit breaker
EC000229 - Handle for power circuit breaker
3038 >> Handles or knobs
31162801
5. Small Equipment (No External Dimension More Than 50 cm)
V11.1 : 27370414

Ordering
1 piece
85364900
Popular Downloads
Dimensions
90 mm
126 mm
150 mm
1.55 kg
Technical
3
0
1
1
3P
Main Circuit 690 V
Main Circuit 50 / 60 Hz
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 160 A
(690 V) 40 °C 160 A
(690 V) 60 °C 145 A
(690 V) 70 °C 130 A
(690 V) 40 °C 160 A
(690 V) 60 °C 145 A
(690 V) 70 °C 130 A
(415 V) 55 °C 116 A
(440 V) 55 °C 116 A
(500 V) 55 °C 110 A
(690 V) 55 °C 65 A
(380 / 400 V) 55 °C 116 A
(220 / 230 / 240 V) 55 °C 116 A
(415 V) 55 °C 116 A
(440 V) 55 °C 116 A
(500 V) 55 °C 110 A
(690 V) 55 °C 65 A
(380 / 400 V) 55 °C 116 A
(220 / 230 / 240 V) 55 °C 116 A
(415 V) 60 °C 116 A
(440 V) 60 °C 116 A
(500 V) 60 °C 110 A
(690 V) 60 °C 65 A
(380 / 400 V) 60 °C 116 A
(220 / 230 / 240 V) 60 °C 116 A
(415 V) 60 °C 116 A
(440 V) 60 °C 116 A
(500 V) 60 °C 110 A
(690 V) 60 °C 65 A
(380 / 400 V) 60 °C 116 A
(220 / 230 / 240 V) 60 °C 116 A
(110 V) 2 Poles in Series, 40 °C 145 A
(220 V) 3 Poles in Series, 40 °C 145 A
(110 V) 2 Poles in Series, 40 °C 145 A
(220 V) 3 Poles in Series, 40 °C 145 A
(110 V) 2 Poles in Series, 40 °C 145 A
(220 V) 3 Poles in Series, 40 °C 145 A
(110 V) 2 Poles in Series, 40 °C 145 A
(220 V) 3 Poles in Series, 40 °C 145 A
(110 V) 2 Poles in Series, 40 °C 145 A
(220 V) 3 Poles in Series, 40 °C 145 A
(110 V) 2 Poles in Series, 40 °C 145 A
(220 V) 3 Poles in Series, 40 °C 145 A
(415 V) 55 kW
(440 V) 75 kW
(500 V) 75 kW
(690 V) 55 kW
(380 / 400 V) 55 kW
(220 / 230 / 240 V) 30 kW
(415 V) 55 kW
(440 V) 75 kW
(500 V) 75 kW
(690 V) 55 kW
(380 / 400 V) 55 kW
(220 / 230 / 240 V) 30 kW
(415 V) 55 kW
(440 V) 75 kW
(500 V) 75 kW
(690 V) 55 kW
(380 / 400 V) 55 kW
(220 / 230 / 240 V) 30 kW
(415 V) 55 kW
(440 V) 75 kW
(500 V) 75 kW
(690 V) 55 kW
(380 / 400 V) 55 kW
(220 / 230 / 240 V) 30 kW
8 x Ie AC-3
8.5 x Ie AC-3e
10 x Ie AC-3
12 x Ie AC-3e
gG Type Fuses 250 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 928 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 160 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 379 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1160 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 536 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 928 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 160 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 379 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1160 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 536 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 2000 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 1000 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 2000 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 1000 A
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
acc. to UL/CSA 600 V
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
acc. to UL/CSA 600 V
Main Circuit 8 kV
(AC-1) 300 cycles per hour
(AC-2 / AC-4) 150 cycles per hour
(AC-3) 300 cycles per hour
(AC-1) 300 cycles per hour
(AC-2 / AC-4) 150 cycles per hour
(AC-3) 300 cycles per hour
5 million
300 cycles per hour
(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
50 Hz 100 ... 250 V
60 Hz 100 ... 250 V
DC Operation 100 ... 250 V
50 Hz 100 ... 250 V
60 Hz 100 ... 250 V
DC Operation 100 ... 250 V
Holding at Max. Rated Control Circuit Voltage 50 Hz 6 V·A
Holding at Max. Rated Control Circuit Voltage 60 Hz 6 V·A
Holding at Max. Rated Control Circuit Voltage DC 3 W
Pull-in at Max. Rated Control Circuit Voltage 50 Hz 130 V·A
Pull-in at Max. Rated Control Circuit Voltage 60 Hz 130 V·A
Pull-in at Max. Rated Control Circuit Voltage DC 135 W
Holding at Max. Rated Control Circuit Voltage 50 Hz 6 V·A
Holding at Max. Rated Control Circuit Voltage 60 Hz 6 V·A
Holding at Max. Rated Control Circuit Voltage DC 3 W
Pull-in at Max. Rated Control Circuit Voltage 50 Hz 130 V·A
Pull-in at Max. Rated Control Circuit Voltage 60 Hz 130 V·A
Pull-in at Max. Rated Control Circuit Voltage DC 135 W
at Rated Operating Conditions per Pole 6 W
Between Coil De-energization and NO Contact Opening 37 ... 47 ms
Between Coil Energization and NO Contact Closing 25 ... 55 ms
Between Coil De-energization and NO Contact Opening 37 ... 47 ms
Between Coil Energization and NO Contact Closing 25 ... 55 ms
Flexible 2 x 10 ... 70 mm²
Rigid Cu-Cable 2 x 10 ... 95 mm²
Flexible 2 x 10 ... 70 mm²
Rigid Cu-Cable 2 x 10 ... 95 mm²
Flexible with Ferrule 2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible 2x0.75 ... 2.5 mm²
Solid 2 x 1 ... 4 mm²
Stranded 2 x 1 .... 4 mm²
Flexible with Ferrule 2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible 2x0.75 ... 2.5 mm²
Solid 2 x 1 ... 4 mm²
Stranded 2 x 1 .... 4 mm²
Flexible 2 x 10 ... 70 mm²
Rigid Cu-Cable 2 x 10 ... 95 mm²
Flexible 2 x 10 ... 70 mm²
Rigid Cu-Cable 2 x 10 ... 95 mm²
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Cable Lug 9 N·m
Main Circuit 8 N·m
Cable Lug 9 N·m
Main Circuit 8 N·m
Double Clamp
Block Contactor
Technical UL/CSA
Main Circuit 600 V
(600 V AC) 160 A
(200 V AC) Three Phase 30 hp
(208 V AC) Three Phase 30 hp
(220 ... 240 V AC) Three Phase 40 hp
(440 ... 480 V AC) Three Phase 75 hp
(550 ... 600 V AC) Three Phase 100 hp
(200 V AC) Three Phase 30 hp
(208 V AC) Three Phase 30 hp
(220 ... 240 V AC) Three Phase 40 hp
(440 ... 480 V AC) Three Phase 75 hp
(550 ... 600 V AC) Three Phase 100 hp
(440 ... 480 V AC) Three Phase 96 A
(550 ... 600 V AC) Three Phase 99 A
(440 ... 480 V AC) Three Phase 96 A
(550 ... 600 V AC) Three Phase 99 A
Environmental
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C
Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C
Close to Contactor for Storage -40 ... 70 °C
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C
Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C
Close to Contactor for Storage -40 ... 70 °C
Without Derating 3000 m
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Yes
Non-hazardous waste is sent to a landfill, where there is no alternative option available within 100km of a facility
Product Efficiency - Product requires less energy to operate compared to similar product on market or older products from the same line
Design for Closing Resource Loops - Standard EN45555 - 87.8 %
Recycled Metal - 37 %
Certificates and Declarations
Container Information
box 1 piece
207 mm
216 mm
150 mm
1.75 kg
7320500476376
External Classifications and Standards
Q
EC000066 - Power contactor, AC switching
EC000066 - Power contactor, AC switching
EC000066 - Power contactor, AC switching
V11.0 : 27371003
39121529
4758 >> Iec Contactors
3706167
4117610
3210068

Ordering
1 piece
85362090
Popular Downloads
Dimensions
55 mm
142.65 mm
122.1 mm
0.98 kg
Technical
(230 V AC) 30 kA
(250 V DC) 3 Poles in Series 100 kA
(400 V AC) 30 kA
(440 V AC) 30 kA
(500 V AC) 20 kA
(690 V AC) 6 kA
(230 V AC) 30 kA
(250 V DC) 3 Poles in Series 100 kA
(400 V AC) 30 kA
(440 V AC) 30 kA
(500 V AC) 20 kA
(690 V AC) 6 kA
(230 V AC) 50 kA
(250 V DC) 100 kA
(400 V AC) 50 kA
(440 V AC) 45 kA
(500 V AC) 20 kA
(690 V AC) 8 kA
(230 V AC) 50 kA
(250 V DC) 100 kA
(400 V AC) 50 kA
(440 V AC) 45 kA
(500 V AC) 20 kA
(690 V AC) 8 kA
975 A
52 ... 65 A
(400 V) Three Phase 30 kW
(400 V) Three Phase 30 kW
Main Circuit 690 V AC
Main Circuit 250 V DC
Main Circuit 690 V AC
Main Circuit 250 V DC
65 A
65 A
65 A
65 A
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit 50 Hz
Main Circuit 60 Hz
0 ... 415 Hz
Main Circuit 8 kV
1000 V
at Rated Operating Conditions per Pole 5.14 ... 8.02 W
3P
Main Circuit 65 A
Housing IP20
Main Circuit Terminals IP10
Housing IP20
Main Circuit Terminals IP10
3
25000 cycle
Nr. Operations 50000 cycle
Screw Terminals
Flexible with Ferrule 1/2x 1 ... 35 mm²
Flexible with Insulated Ferrule 1/2x 1 ... 35 mm²
Flexible 1/2x 1 ... 35 mm²
Rigid 1/2x 1 ... 4 mm²
Solid 1/2x 1 ... 4 mm²
Stranded 1/2x 1 ... 50 mm²
Flexible with Ferrule 1/2x 1 ... 35 mm²
Flexible with Insulated Ferrule 1/2x 1 ... 35 mm²
Flexible 1/2x 1 ... 35 mm²
Rigid 1/2x 1 ... 4 mm²
Solid 1/2x 1 ... 4 mm²
Stranded 1/2x 1 ... 50 mm²
Main Circuit 4 N·m
Main Circuit 16 mm
Pozidriv 2
1 ... 6
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Electrical Conductive Board, Horizontal - Up to 1000 V 1.5 mm
Electrical Conductive Board, Horizontal - Up to 400 V 0 mm
Electrical Conductive Board, Horizontal - Up to 690 V 1.5 mm
Electrical Conductive Board, Vertical 75 mm
Other Device Same Type, Horizontal 0 mm
Other Device Same Type, Vertical 150 mm
Electrical Conductive Board, Horizontal - Up to 1000 V 1.5 mm
Electrical Conductive Board, Horizontal - Up to 400 V 0 mm
Electrical Conductive Board, Horizontal - Up to 690 V 1.5 mm
Electrical Conductive Board, Vertical 75 mm
Other Device Same Type, Horizontal 0 mm
Other Device Same Type, Vertical 150 mm
Rotary Handle
ON / OFF / TRIP
CSA 22.2 No. 14
IEC/EN 60947-1
IEC/EN 60947-2
IEC/EN 60947-4-1
UL 60947-4-1
CSA 22.2 No. 14
IEC/EN 60947-1
IEC/EN 60947-2
IEC/EN 60947-4-1
UL 60947-4-1
Technical UL/CSA
Manual Self-Protected Combination Controllers (Type E), (480Y / 277 V AC) 65 kA
Manual Self-Protected Combination Controllers (Type E), (600Y / 347 V AC) 30 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 30 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 30 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (600Y / 347 V AC) 30 kA
Manual Self-Protected Combination Controllers (Type E), (480Y / 277 V AC) 65 kA
Manual Self-Protected Combination Controllers (Type E), (600Y / 347 V AC) 30 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 30 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 30 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (600Y / 347 V AC) 30 kA
Main Circuit 600 V AC
(200 V AC) Three Phase 20 Hp
(208 V AC) Three Phase 20 Hp
(220 ... 240 V AC) Three Phase 20 Hp
(440 ... 480 V AC) Three Phase 50 Hp
(550 ... 600 V AC) Three Phase 60 Hp
(200 V AC) Three Phase 20 Hp
(208 V AC) Three Phase 20 Hp
(220 ... 240 V AC) Three Phase 20 Hp
(440 ... 480 V AC) Three Phase 50 Hp
(550 ... 600 V AC) Three Phase 60 Hp
(200 V AC) Three Phase 62.1 A
(208 V AC) Three Phase 59.4 A
(220 ... 240 V AC) Three Phase 54 A
(440 ... 480 V AC) Three Phase 65 A
(550 ... 600 V AC) Three Phase 62 A
(200 V AC) Three Phase 62.1 A
(208 V AC) Three Phase 59.4 A
(220 ... 240 V AC) Three Phase 54 A
(440 ... 480 V AC) Three Phase 65 A
(550 ... 600 V AC) Three Phase 62 A
(200 V AC) Three Phase 334 A
(208 V AC) Three Phase 321 A
(220 ... 240 V AC) Three Phase 290 A
(440 ... 480 V AC) Three Phase 363 A
(550 ... 600 V AC) Three Phase 348 A
(200 V AC) Three Phase 334 A
(208 V AC) Three Phase 321 A
(220 ... 240 V AC) Three Phase 290 A
(440 ... 480 V AC) Three Phase 363 A
(550 ... 600 V AC) Three Phase 348 A
(600 V AC) 65 A
Flexible 1/2x 16-0 AWG
Stranded 1/2x 16-0 AWG
Flexible 1/2x 16-0 AWG
Stranded 1/2x 16-0 AWG
Main Circuit 35 in·lb
Environmental
Operation -25 ... +70 °C
Operation Compensated -25 ... +60 °C
Storage -50 ... +80 °C
Operation -25 ... +70 °C
Operation Compensated -25 ... +60 °C
Storage -50 ... +80 °C
Yes
2000 m
11 ms Pulse 25g
Mounted on Mounting Plate: 5g 3 ... 150 Hz
Mounted on DIN-Rail: 4g 3 ... 150 Hz
Mounted on Mounting Plate: 5g 3 ... 150 Hz
Mounted on DIN-Rail: 4g 3 ... 150 Hz
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Certificates and Declarations
Container Information
box 1 piece
64 mm
177 mm
140 mm
1.1 kg
4013614486111
carton 12 piece
330 mm
400 mm
320 mm
13 kg
4013614503979
External Classifications and Standards
F
EC000074 - Motor protection circuit-breaker
EC000074 - Motor protection circuit-breaker
V11.0 : 27370401
39121521
4731 >> Manual Starters
3707290
4364126
3110057

Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Ordering
4376648
8015644383244
1 piece
85389099
Dimensions
125 mm
175 mm
195 mm
1.9 kg
Container Information
1 piece
140 mm
175 mm
180 mm
1.665 kg
8015644383244
Additional Information
Accessories for Emax
Accessory
Accessory
E1, E2, E3, E4, E6, T8
SACE Emax, SACE Tmax T
Technical
Loose or configurable
AC/DC
220 ... 250 V AC/DC
IEC
Certificates and Declarations
External Classifications and Standards
Q
5. Small Equipment (No External Dimension More Than 50 cm)

ABB EcoSolutions
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Environmental
Ordering
KXTFYUC5
3642178
4381380
8015644070502
1 piece
85389099
Dimensions
0.143 kg
Container Information
box 1 piece
110 mm
60 mm
140 mm
0.15 kg
8015644070502
Additional Information
Accessories for Tmax XT
Accessory
Accessory
XT5
XT6
XT5
XT6
SACE Tamx XT
Technical
Loose or configurable
AC/DC
1 piece
220...240 V AC
220...250 V DC
220...240 V AC
220...250 V DC
IEC60947-2
UL489
IEC60947-2
UL489
Certificates and Declarations
External Classifications and Standards
EC001022 - Under voltage coil
EC001022 - Under voltage coil
4148 >> Under voltage coil
39121010
5. Small Equipment (No External Dimension More Than 50 cm)
V11.1 : 27370417

Ordering
0.00
850490
850490 -- ELECTRICAL MACHINERY AND EQUIPMENT AND PARTS THEREOF; SOUND RECORDERS AND REPRODUCERS, TELEVISION IMAGE AND SOUND RECORDERS AND REPRODUCERS, AND PARTS AND ACCESSORIES OF SUCH ARTICLES;Electrical transformers, static converters (for example, rectifiers) and inductors;Parts
DriveWindow 2.x (Win2000, XP, Vista, Win7/32 and 64-bit, Win8/32 and 64-bit), incl. RUSB-02 connecti
No
1 piece
1 piece
No
piece
Dimensions
0.579 kg
1.276 lb
0.579 kg
1.276 lb
22 mm
0.866 in
22 mm
0.866 in
26 mm
1.024 in
26 mm
1.024 in
36 mm
1.417 in
36 mm
1.417 in
1 carton
Technical
Undefined
Environmental
Product Not in WEEE Scope
External Classifications and Standards
39120000
39122004
39120000
39122004

Ordering
1 piece
85364900
Popular Downloads
Dimensions
55 mm
111 mm
125.5 mm
0.95 kg
Technical
3
0
0
0
3P
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60335-2-40 LZGH2 A2L, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60335-2-40 LZGH2 A2L, CSA C22.2 No. 60947-1:22, CSA C22.2 No. 60947-4-1:22
Main Circuit 690 V
Control Circuit 50 / 60 Hz
Main Circuit 50 / 60 Hz
Control Circuit 50 / 60 Hz
Main Circuit 50 / 60 Hz
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 105 A
(690 V) 40 °C 100 A
(690 V) 60 °C 80 A
(690 V) 70 °C 70 A
(690 V) 40 °C 100 A
(690 V) 60 °C 80 A
(690 V) 70 °C 70 A
(415 V) 60 °C 53 A
(440 V) 60 °C 53 A
(500 V) 60 °C 45 A
(690 V) 60 °C 35 A
(380 / 400 V) 60 °C 53 A
(220 / 230 / 240 V) 60 °C 53 A
(415 V) 60 °C 53 A
(440 V) 60 °C 53 A
(500 V) 60 °C 45 A
(690 V) 60 °C 35 A
(380 / 400 V) 60 °C 53 A
(220 / 230 / 240 V) 60 °C 53 A
(415 V) 60 °C 53 A
(440 V) 60 °C 53 A
(500 V) 60 °C 45 A
(690 V) 60 °C 35 A
(380 / 400 V) 60 °C 53 A
(220 / 230 / 240 V) 60 °C 53 A
(415 V) 60 °C 53 A
(440 V) 60 °C 53 A
(500 V) 60 °C 45 A
(690 V) 60 °C 35 A
(380 / 400 V) 60 °C 53 A
(220 / 230 / 240 V) 60 °C 53 A
(110 V) 2 Poles in Series, 40 °C 100 A
(110 V) 2 Poles in Series, 60 °C 80 A
(110 V) 2 Poles in Series, 70 °C 70 A
(110 V) 3 Poles in Series, 40 °C 100 A
(110 V) 3 Poles in Series, 60 °C 80 A
(110 V) 3 Poles in Series, 70 °C 70 A
(220 V) 3 Poles in Series, 40 °C 100 A
(220 V) 3 Poles in Series, 60 °C 80 A
(220 V) 3 Poles in Series, 70 °C 70 A
(72 V) 1-Pole, 40 °C 100 A
(72 V) 1-Pole, 60 °C 80 A
(72 V) 1-Pole, 70 °C 70 A
(72 V) 2 Poles in Series, 40 °C 100 A
(72 V) 2 Poles in Series, 60 °C 80 A
(72 V) 2 Poles in Series, 70 °C 70 A
(72 V) 3 Poles in Series, 40 °C 100 A
(72 V) 3 Poles in Series, 60 °C 80 A
(72 V) 3 Poles in Series, 70 °C 70 A
(110 V) 2 Poles in Series, 40 °C 100 A
(110 V) 2 Poles in Series, 60 °C 80 A
(110 V) 2 Poles in Series, 70 °C 70 A
(110 V) 3 Poles in Series, 40 °C 100 A
(110 V) 3 Poles in Series, 60 °C 80 A
(110 V) 3 Poles in Series, 70 °C 70 A
(220 V) 3 Poles in Series, 40 °C 100 A
(220 V) 3 Poles in Series, 60 °C 80 A
(220 V) 3 Poles in Series, 70 °C 70 A
(72 V) 1-Pole, 40 °C 100 A
(110 V) 2 Poles in Series, 40 °C 100 A
(110 V) 2 Poles in Series, 60 °C 80 A
(110 V) 2 Poles in Series, 70 °C 70 A
(110 V) 3 Poles in Series, 40 °C 100 A
(110 V) 3 Poles in Series, 60 °C 80 A
(110 V) 3 Poles in Series, 70 °C 70 A
(220 V) 3 Poles in Series, 40 °C 100 A
(220 V) 3 Poles in Series, 60 °C 80 A
(220 V) 3 Poles in Series, 70 °C 70 A
(72 V) 1-Pole, 40 °C 100 A
(72 V) 1-Pole, 60 °C 80 A
(72 V) 1-Pole, 70 °C 70 A
(72 V) 2 Poles in Series, 40 °C 100 A
(72 V) 2 Poles in Series, 60 °C 80 A
(72 V) 2 Poles in Series, 70 °C 70 A
(72 V) 3 Poles in Series, 40 °C 100 A
(72 V) 3 Poles in Series, 60 °C 80 A
(72 V) 3 Poles in Series, 70 °C 70 A
(110 V) 2 Poles in Series, 40 °C 100 A
(110 V) 2 Poles in Series, 60 °C 80 A
(110 V) 2 Poles in Series, 70 °C 70 A
(110 V) 3 Poles in Series, 40 °C 100 A
(110 V) 3 Poles in Series, 60 °C 80 A
(110 V) 3 Poles in Series, 70 °C 70 A
(220 V) 3 Poles in Series, 40 °C 100 A
(220 V) 3 Poles in Series, 60 °C 80 A
(220 V) 3 Poles in Series, 70 °C 70 A
(72 V) 1-Pole, 40 °C 100 A
(110 V) 2 Poles in Series, 40 °C 100 A
(110 V) 2 Poles in Series, 60 °C 80 A
(110 V) 2 Poles in Series, 70 °C 70 A
(110 V) 3 Poles in Series, 40 °C 100 A
(110 V) 3 Poles in Series, 60 °C 80 A
(110 V) 3 Poles in Series, 70 °C 70 A
(220 V) 3 Poles in Series, 40 °C 100 A
(220 V) 3 Poles in Series, 60 °C 80 A
(220 V) 3 Poles in Series, 70 °C 70 A
(72 V) 1-Pole, 40 °C 100 A
(72 V) 1-Pole, 60 °C 80 A
(72 V) 1-Pole, 70 °C 70 A
(72 V) 2 Poles in Series, 40 °C 100 A
(72 V) 2 Poles in Series, 60 °C 80 A
(72 V) 2 Poles in Series, 70 °C 70 A
(72 V) 3 Poles in Series, 40 °C 100 A
(72 V) 3 Poles in Series, 60 °C 80 A
(72 V) 3 Poles in Series, 70 °C 70 A
(110 V) 2 Poles in Series, 40 °C 100 A
(110 V) 2 Poles in Series, 60 °C 80 A
(110 V) 2 Poles in Series, 70 °C 70 A
(110 V) 3 Poles in Series, 40 °C 100 A
(110 V) 3 Poles in Series, 60 °C 80 A
(110 V) 3 Poles in Series, 70 °C 70 A
(220 V) 3 Poles in Series, 40 °C 100 A
(220 V) 3 Poles in Series, 60 °C 80 A
(220 V) 3 Poles in Series, 70 °C 70 A
(72 V) 1-Pole, 40 °C 100 A
(400 V) 22 kW
(415 V) 30 kW
(440 V) 30 kW
(500 V) 30 kW
(690 V) 30 kW
(380 / 400 V) 22 kW
(220 / 230 / 240 V) 15 kW
(400 V) 22 kW
(415 V) 30 kW
(440 V) 30 kW
(500 V) 30 kW
(690 V) 30 kW
(380 / 400 V) 22 kW
(220 / 230 / 240 V) 15 kW
(415 V) 30 kW
(440 V) 30 kW
(500 V) 30 kW
(690 V) 30 kW
(380 / 400 V) 22 kW
(220 / 230 / 240 V) 15 kW
(415 V) 30 kW
(440 V) 30 kW
(500 V) 30 kW
(690 V) 30 kW
(380 / 400 V) 22 kW
(220 / 230 / 240 V) 15 kW
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 600 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 350 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 600 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 350 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 950 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 600 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 950 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 600 A
acc. to IEC 60947-4-1 690 V
acc. to UL/CSA 600 V
acc. to IEC 60947-4-1 690 V
acc. to UL/CSA 600 V
6 kV
(AC-1) 600 cycles per hour
(AC-2 / AC-4) 150 cycles per hour
(AC-3) 1200 cycles per hour
(AC-1) 600 cycles per hour
(AC-2 / AC-4) 150 cycles per hour
(AC-3) 1200 cycles per hour
3600 cycles per hour
50 Hz 100 ... 250 V
60 Hz 100 ... 250 V
DC Operation 100 ... 250 V
50 Hz 100 ... 250 V
60 Hz 100 ... 250 V
DC Operation 100 ... 250 V
Average Holding Value 50 / 60 Hz 4 V·A
Average Holding Value 50 Hz 4 V·A
Average Holding Value 60 Hz 4 V·A
Average Holding Value DC 2 W
Average Holding Value, from Warm State 2 W
Average Holding Value 50 / 60 Hz 4 V·A
Average Holding Value 50 Hz 4 V·A
Average Holding Value 60 Hz 4 V·A
Average Holding Value DC 2 W
Average Holding Value, from Warm State 2 W
at Rated Operating Conditions AC-1 per Pole 6.3 W
at Rated Operating Conditions AC-3 per Pole 1.7 W
at Rated Operating Conditions AC-1 per Pole 6.3 W
at Rated Operating Conditions AC-3 per Pole 1.7 W
Between Coil De-energization and NC Contact Closing 19 ... 105 ms
Between Coil De-energization and NO Contact Opening 17 ... 100 ms
Between Coil Energization and NC Contact Opening 38 ... 95 ms
Between Coil Energization and NO Contact Closing 42 ... 100 ms
Between Coil De-energization and NC Contact Closing 19 ... 105 ms
Between Coil De-energization and NO Contact Opening 17 ... 100 ms
Between Coil Energization and NC Contact Opening 38 ... 95 ms
Between Coil Energization and NO Contact Closing 42 ... 100 ms
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
2 x M4 or 2 x M6 Screws Placed Diagonally
Flexible with Ferrule 1/2x 4 ... 35 mm²
Flexible with Insulated Ferrule 1/2x 4 ... 35 mm²
Rigid Stranded 1/2x 6 ... 35 mm²
Flexible with Ferrule 1/2x 4 ... 35 mm²
Flexible with Insulated Ferrule 1/2x 4 ... 35 mm²
Rigid Stranded 1/2x 6 ... 35 mm²
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Rigid Solid 1/2x 1 ... 2.5 mm²
Rigid Stranded 1/2x 1 ... 2.5 mm²
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Rigid Solid 1/2x 1 ... 2.5 mm²
Rigid Stranded 1/2x 1 ... 2.5 mm²
Control Circuit 10 mm
Main Circuit 16 mm
Control Circuit 10 mm
Main Circuit 16 mm
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Pozidriv PZ
Control Circuit 1.2 N·m
Main Circuit 4 N·m
Control Circuit 1.2 N·m
Main Circuit 4 N·m
Screw Terminals
Block Contactor
Technical UL/CSA
Main Circuit 600 V
(600 V AC) 80 A
(120 V AC) Single Phase 3 hp
(200 ... 208 V AC) Three Phase 15 hp
(220 ... 240 V AC) Three Phase 20 hp
(240 V AC) Single Phase 10 hp
(440 ... 480 V AC) Three Phase 40 hp
(550 ... 600 V AC) Three Phase 50 hp
(120 V AC) Single Phase 3 hp
(200 ... 208 V AC) Three Phase 15 hp
(220 ... 240 V AC) Three Phase 20 hp
(240 V AC) Single Phase 10 hp
(440 ... 480 V AC) Three Phase 40 hp
(550 ... 600 V AC) Three Phase 50 hp
Rigid Stranded 1/2x 10-2 AWG
Rigid Solid 1/2x 18-14 AWG
Rigid Stranded 1/2x 18-14 AWG
Rigid Solid 1/2x 18-14 AWG
Rigid Stranded 1/2x 18-14 AWG
Control Circuit 11 in·lb
Main Circuit 35 in·lb
Control Circuit 11 in·lb
Main Circuit 35 in·lb
(120 V AC) Single Phase 34 A
(200 ... 208 V AC) Three Phase 48.3 A
(220 ... 240 V AC) Three Phase 54 A
(240 V AC) Single Phase 50 A
(440 ... 480 V AC) Three Phase 52 A
(550 ... 600 V AC) Three Phase 52 A
(120 V AC) Single Phase 34 A
(200 ... 208 V AC) Three Phase 48.3 A
(220 ... 240 V AC) Three Phase 54 A
(240 V AC) Single Phase 50 A
(440 ... 480 V AC) Three Phase 52 A
(550 ... 600 V AC) Three Phase 52 A
Environmental
Close to Contactor Fitted with Thermal O/L Relay -40 ... 70 °C
Close to Contactor without Thermal O/L Relay -40 ... 70 °C
Close to Contactor for Storage -60 ... +80 °C
Close to Contactor Fitted with Thermal O/L Relay -40 ... 70 °C
Close to Contactor without Thermal O/L Relay -40 ... 70 °C
Close to Contactor for Storage -60 ... +80 °C
Category B according to IEC 60947-1 Annex Q
Without Derating 3000 m
Closed, Shock Direction: A 25 g
Closed, Shock Direction: B1 25 g
Closed, Shock Direction: B2 15 g
Closed, Shock Direction: C1 25 g
Closed, Shock Direction: C2 25 g
Open, Shock Direction: B1 5 g
Closed, Shock Direction: A 25 g
Closed, Shock Direction: B1 25 g
Closed, Shock Direction: B2 15 g
Closed, Shock Direction: C1 25 g
Closed, Shock Direction: C2 25 g
Open, Shock Direction: B1 5 g
3g Closed Position & 3g Open Position 5 ... 300 Hz
3
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
0112cbf0-8178-43d5-afe5-258ce47d676c France
203d519c-f023-42f6-a384-24e520c6d8b3 Germany
f103c547-b240-47ad-bef9-7d2e65ea3e7e Sweden
510faff0-7666-44b3-a702-3590e5746524 Poland
1fe30ce2-7e6a-4ae1-998d-3769559d02ee France
64d6929f-434b-4b58-a91b-637dd7ba6d3a Germany
ca5fbd4b-0e51-4417-9a58-acb0708afe24 Finland
87e53397-35a1-42ad-ba68-befc12cedfda Italy
b9873bdd-a59a-477a-a35d-3d664d0d022c Netherlands
aa64e587-e9f0-4332-b755-e5cf0583458d Greece
c1fac5cf-fc89-4d9a-b38b-55ec371a046e Poland
8ccb50f5-9561-448d-bfb5-ae5746b35c4c Norway
c8130e79-9338-41f4-b1de-4a54f9089e95 Germany
149edc09-3bb3-4a16-9942-bfa6433dcd08 Denmark
808a8d20-e14e-4644-b47e-6b965fc01ad3 Germany
1e6e9d74-c295-4bb9-aec1-88c8d5d2f8b5 Czech Republic
3ff4f900-29bc-4771-ae06-31af5fc42ac6 Poland
8404309e-8ddd-495b-aa8b-4dbc56b5097d Portugal
a375f64e-e126-4d9e-ae9a-56689d4570d6 Hungary
79087227-6a51-4db5-982d-ee84f921f0fc Belgium
28c79fd5-8c97-4f39-b4d3-005d2419cbdb Spain
921f5c0f-583b-49f0-b414-485614d6643b Sweden
79f17cd0-bd46-424d-8f63-37d57e4af7ad Bulgaria
479d4957-05c4-421d-a5bf-045bb0cd69e6 Germany
203d519c-f023-42f6-a384-24e520c6d8b3 Germany
f103c547-b240-47ad-bef9-7d2e65ea3e7e Sweden
510faff0-7666-44b3-a702-3590e5746524 Poland
1fe30ce2-7e6a-4ae1-998d-3769559d02ee France
64d6929f-434b-4b58-a91b-637dd7ba6d3a Germany
ca5fbd4b-0e51-4417-9a58-acb0708afe24 Finland
87e53397-35a1-42ad-ba68-befc12cedfda Italy
b9873bdd-a59a-477a-a35d-3d664d0d022c Netherlands
aa64e587-e9f0-4332-b755-e5cf0583458d Greece
c1fac5cf-fc89-4d9a-b38b-55ec371a046e Poland
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Yes
FSC Recycled Paper - 94.6 %
Recycled Metal - 28.2 %
Certificates and Declarations
Container Information
box 1 piece
150 mm
150 mm
97 mm
1.05 kg
3471523132337
box 10 piece
250 mm
300 mm
300 mm
10.5 kg
External Classifications and Standards
Q
EC000066 - Power contactor, AC switching
EC000066 - Power contactor, AC switching
EC000066 - Power contactor, AC switching
V11.0 : 27371003
39121529
4758 >> Iec Contactors
3707016
3210039

Ordering
1 piece
85364900
Popular Downloads
Dimensions
55 mm
111 mm
125.5 mm
0.97 kg
Technical
3
0
0
0
3P
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60335-2-40 LZGH2 A2L, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60335-2-40 LZGH2 A2L, CSA C22.2 No. 60947-1:22, CSA C22.2 No. 60947-4-1:22
Main Circuit 690 V
Control Circuit 50 / 60 Hz
Main Circuit 50 / 60 Hz
Control Circuit 50 / 60 Hz
Main Circuit 50 / 60 Hz
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 105 A
(690 V) 40 °C 100 A
(690 V) 60 °C 80 A
(690 V) 70 °C 70 A
(690 V) 40 °C 100 A
(690 V) 60 °C 80 A
(690 V) 70 °C 70 A
(415 V) 60 °C 53 A
(440 V) 60 °C 53 A
(500 V) 60 °C 45 A
(690 V) 60 °C 35 A
(380 / 400 V) 60 °C 53 A
(220 / 230 / 240 V) 60 °C 53 A
(415 V) 60 °C 53 A
(440 V) 60 °C 53 A
(500 V) 60 °C 45 A
(690 V) 60 °C 35 A
(380 / 400 V) 60 °C 53 A
(220 / 230 / 240 V) 60 °C 53 A
(415 V) 60 °C 53 A
(440 V) 60 °C 53 A
(500 V) 60 °C 45 A
(690 V) 60 °C 35 A
(380 / 400 V) 60 °C 53 A
(220 / 230 / 240 V) 60 °C 53 A
(415 V) 60 °C 53 A
(440 V) 60 °C 53 A
(500 V) 60 °C 45 A
(690 V) 60 °C 35 A
(380 / 400 V) 60 °C 53 A
(220 / 230 / 240 V) 60 °C 53 A
(110 V) 2 Poles in Series, 40 °C 100 A
(110 V) 2 Poles in Series, 60 °C 80 A
(110 V) 2 Poles in Series, 70 °C 70 A
(110 V) 3 Poles in Series, 40 °C 100 A
(110 V) 3 Poles in Series, 60 °C 80 A
(110 V) 3 Poles in Series, 70 °C 70 A
(220 V) 3 Poles in Series, 40 °C 100 A
(220 V) 3 Poles in Series, 60 °C 80 A
(220 V) 3 Poles in Series, 70 °C 70 A
(72 V) 1-Pole, 40 °C 100 A
(72 V) 1-Pole, 60 °C 80 A
(72 V) 1-Pole, 70 °C 70 A
(72 V) 2 Poles in Series, 40 °C 100 A
(72 V) 2 Poles in Series, 60 °C 80 A
(72 V) 2 Poles in Series, 70 °C 70 A
(72 V) 3 Poles in Series, 40 °C 100 A
(72 V) 3 Poles in Series, 60 °C 80 A
(72 V) 3 Poles in Series, 70 °C 70 A
(110 V) 2 Poles in Series, 40 °C 100 A
(110 V) 2 Poles in Series, 60 °C 80 A
(110 V) 2 Poles in Series, 70 °C 70 A
(110 V) 3 Poles in Series, 40 °C 100 A
(110 V) 3 Poles in Series, 60 °C 80 A
(110 V) 3 Poles in Series, 70 °C 70 A
(220 V) 3 Poles in Series, 40 °C 100 A
(220 V) 3 Poles in Series, 60 °C 80 A
(220 V) 3 Poles in Series, 70 °C 70 A
(72 V) 1-Pole, 40 °C 100 A
(110 V) 2 Poles in Series, 40 °C 100 A
(110 V) 2 Poles in Series, 60 °C 80 A
(110 V) 2 Poles in Series, 70 °C 70 A
(110 V) 3 Poles in Series, 40 °C 100 A
(110 V) 3 Poles in Series, 60 °C 80 A
(110 V) 3 Poles in Series, 70 °C 70 A
(220 V) 3 Poles in Series, 40 °C 100 A
(220 V) 3 Poles in Series, 60 °C 80 A
(220 V) 3 Poles in Series, 70 °C 70 A
(72 V) 1-Pole, 40 °C 100 A
(72 V) 1-Pole, 60 °C 80 A
(72 V) 1-Pole, 70 °C 70 A
(72 V) 2 Poles in Series, 40 °C 100 A
(72 V) 2 Poles in Series, 60 °C 80 A
(72 V) 2 Poles in Series, 70 °C 70 A
(72 V) 3 Poles in Series, 40 °C 100 A
(72 V) 3 Poles in Series, 60 °C 80 A
(72 V) 3 Poles in Series, 70 °C 70 A
(110 V) 2 Poles in Series, 40 °C 100 A
(110 V) 2 Poles in Series, 60 °C 80 A
(110 V) 2 Poles in Series, 70 °C 70 A
(110 V) 3 Poles in Series, 40 °C 100 A
(110 V) 3 Poles in Series, 60 °C 80 A
(110 V) 3 Poles in Series, 70 °C 70 A
(220 V) 3 Poles in Series, 40 °C 100 A
(220 V) 3 Poles in Series, 60 °C 80 A
(220 V) 3 Poles in Series, 70 °C 70 A
(72 V) 1-Pole, 40 °C 100 A
(110 V) 2 Poles in Series, 40 °C 100 A
(110 V) 2 Poles in Series, 60 °C 80 A
(110 V) 2 Poles in Series, 70 °C 70 A
(110 V) 3 Poles in Series, 40 °C 100 A
(110 V) 3 Poles in Series, 60 °C 80 A
(110 V) 3 Poles in Series, 70 °C 70 A
(220 V) 3 Poles in Series, 40 °C 100 A
(220 V) 3 Poles in Series, 60 °C 80 A
(220 V) 3 Poles in Series, 70 °C 70 A
(72 V) 1-Pole, 40 °C 100 A
(72 V) 1-Pole, 60 °C 80 A
(72 V) 1-Pole, 70 °C 70 A
(72 V) 2 Poles in Series, 40 °C 100 A
(72 V) 2 Poles in Series, 60 °C 80 A
(72 V) 2 Poles in Series, 70 °C 70 A
(72 V) 3 Poles in Series, 40 °C 100 A
(72 V) 3 Poles in Series, 60 °C 80 A
(72 V) 3 Poles in Series, 70 °C 70 A
(110 V) 2 Poles in Series, 40 °C 100 A
(110 V) 2 Poles in Series, 60 °C 80 A
(110 V) 2 Poles in Series, 70 °C 70 A
(110 V) 3 Poles in Series, 40 °C 100 A
(110 V) 3 Poles in Series, 60 °C 80 A
(110 V) 3 Poles in Series, 70 °C 70 A
(220 V) 3 Poles in Series, 40 °C 100 A
(220 V) 3 Poles in Series, 60 °C 80 A
(220 V) 3 Poles in Series, 70 °C 70 A
(72 V) 1-Pole, 40 °C 100 A
(400 V) 22 kW
(415 V) 30 kW
(440 V) 30 kW
(500 V) 30 kW
(690 V) 30 kW
(380 / 400 V) 22 kW
(220 / 230 / 240 V) 15 kW
(400 V) 22 kW
(415 V) 30 kW
(440 V) 30 kW
(500 V) 30 kW
(690 V) 30 kW
(380 / 400 V) 22 kW
(220 / 230 / 240 V) 15 kW
(415 V) 30 kW
(440 V) 30 kW
(500 V) 30 kW
(690 V) 30 kW
(380 / 400 V) 22 kW
(220 / 230 / 240 V) 15 kW
(415 V) 30 kW
(440 V) 30 kW
(500 V) 30 kW
(690 V) 30 kW
(380 / 400 V) 22 kW
(220 / 230 / 240 V) 15 kW
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 600 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 350 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 600 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 350 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 950 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 600 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 950 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 600 A
acc. to IEC 60947-4-1 690 V
acc. to UL/CSA 600 V
acc. to IEC 60947-4-1 690 V
acc. to UL/CSA 600 V
6 kV
(AC-1) 600 cycles per hour
(AC-2 / AC-4) 150 cycles per hour
(AC-3) 1200 cycles per hour
(AC-1) 600 cycles per hour
(AC-2 / AC-4) 150 cycles per hour
(AC-3) 1200 cycles per hour
3600 cycles per hour
50 Hz 24 ... 60 V
60 Hz 24 ... 60 V
DC Operation 20 ... 60 V
50 Hz 24 ... 60 V
60 Hz 24 ... 60 V
DC Operation 20 ... 60 V
Average Holding Value 50 / 60 Hz 4 V·A
Average Holding Value 50 Hz 4 V·A
Average Holding Value 60 Hz 4 V·A
Average Holding Value DC 2 W
Average Holding Value, from Warm State 2 W
Average Holding Value 50 / 60 Hz 4 V·A
Average Holding Value 50 Hz 4 V·A
Average Holding Value 60 Hz 4 V·A
Average Holding Value DC 2 W
Average Holding Value, from Warm State 2 W
at Rated Operating Conditions AC-1 per Pole 6.3 W
at Rated Operating Conditions AC-3 per Pole 1.7 W
at Rated Operating Conditions AC-1 per Pole 6.3 W
at Rated Operating Conditions AC-3 per Pole 1.7 W
Between Coil De-energization and NC Contact Closing 19 ... 105 ms
Between Coil De-energization and NO Contact Opening 17 ... 100 ms
Between Coil Energization and NC Contact Opening 38 ... 95 ms
Between Coil Energization and NO Contact Closing 42 ... 100 ms
Between Coil De-energization and NC Contact Closing 19 ... 105 ms
Between Coil De-energization and NO Contact Opening 17 ... 100 ms
Between Coil Energization and NC Contact Opening 38 ... 95 ms
Between Coil Energization and NO Contact Closing 42 ... 100 ms
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
2 x M4 or 2 x M6 Screws Placed Diagonally
Flexible with Ferrule 1/2x 4 ... 35 mm²
Flexible with Insulated Ferrule 1/2x 4 ... 35 mm²
Rigid Stranded 1/2x 6 ... 35 mm²
Flexible with Ferrule 1/2x 4 ... 35 mm²
Flexible with Insulated Ferrule 1/2x 4 ... 35 mm²
Rigid Stranded 1/2x 6 ... 35 mm²
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Rigid Solid 1/2x 1 ... 2.5 mm²
Rigid Stranded 1/2x 1 ... 2.5 mm²
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Rigid Solid 1/2x 1 ... 2.5 mm²
Rigid Stranded 1/2x 1 ... 2.5 mm²
Control Circuit 10 mm
Main Circuit 16 mm
Control Circuit 10 mm
Main Circuit 16 mm
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Pozidriv PZ
Control Circuit 1.2 N·m
Main Circuit 4 N·m
Control Circuit 1.2 N·m
Main Circuit 4 N·m
Screw Terminals
Block Contactor
Technical UL/CSA
Main Circuit 600 V
(600 V AC) 80 A
(120 V AC) Single Phase 3 hp
(200 ... 208 V AC) Three Phase 15 hp
(220 ... 240 V AC) Three Phase 20 hp
(240 V AC) Single Phase 10 hp
(440 ... 480 V AC) Three Phase 40 hp
(550 ... 600 V AC) Three Phase 50 hp
(120 V AC) Single Phase 3 hp
(200 ... 208 V AC) Three Phase 15 hp
(220 ... 240 V AC) Three Phase 20 hp
(240 V AC) Single Phase 10 hp
(440 ... 480 V AC) Three Phase 40 hp
(550 ... 600 V AC) Three Phase 50 hp
Rigid Stranded 1/2x 10-2 AWG
Rigid Solid 1/2x 18-14 AWG
Rigid Stranded 1/2x 18-14 AWG
Rigid Solid 1/2x 18-14 AWG
Rigid Stranded 1/2x 18-14 AWG
Control Circuit 11 in·lb
Main Circuit 35 in·lb
Control Circuit 11 in·lb
Main Circuit 35 in·lb
(120 V AC) Single Phase 34 A
(200 ... 208 V AC) Three Phase 48.3 A
(220 ... 240 V AC) Three Phase 54 A
(240 V AC) Single Phase 50 A
(440 ... 480 V AC) Three Phase 52 A
(550 ... 600 V AC) Three Phase 52 A
(120 V AC) Single Phase 34 A
(200 ... 208 V AC) Three Phase 48.3 A
(220 ... 240 V AC) Three Phase 54 A
(240 V AC) Single Phase 50 A
(440 ... 480 V AC) Three Phase 52 A
(550 ... 600 V AC) Three Phase 52 A
Environmental
Close to Contactor Fitted with Thermal O/L Relay -40 ... 70 °C
Close to Contactor without Thermal O/L Relay -40 ... 70 °C
Close to Contactor for Storage -60 ... +80 °C
Close to Contactor Fitted with Thermal O/L Relay -40 ... 70 °C
Close to Contactor without Thermal O/L Relay -40 ... 70 °C
Close to Contactor for Storage -60 ... +80 °C
Category B according to IEC 60947-1 Annex Q
Without Derating 3000 m
Closed, Shock Direction: A 25 g
Closed, Shock Direction: B1 25 g
Closed, Shock Direction: B2 15 g
Closed, Shock Direction: C1 25 g
Closed, Shock Direction: C2 25 g
Open, Shock Direction: B1 5 g
Closed, Shock Direction: A 25 g
Closed, Shock Direction: B1 25 g
Closed, Shock Direction: B2 15 g
Closed, Shock Direction: C1 25 g
Closed, Shock Direction: C2 25 g
Open, Shock Direction: B1 5 g
3g Closed Position & 3g Open Position 5 ... 300 Hz
3
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
71c82dcf-217b-416b-9985-2f7ef9946893 France
d7b62b42-47ae-4d94-87de-e93def0da041 Poland
f5d8d1fc-8bf8-48c5-bfdb-20cef1721db8 Belgium
41d365b9-6787-41d9-8e0e-bc7c12f402f2 Norway
1b310530-6a78-45e8-9afb-ec052a4c4935 Germany
94f6a63c-786b-43d1-99a4-941a55113656 Poland
9a382b80-274b-482a-93d3-78f69d135dbd Netherlands
c2c5f2f9-f229-4952-942b-6dc8c6686ea8 Hungary
bb467480-aa41-4817-8b2d-d219427d26de Estonia
f672d4df-567d-4a50-adfb-77fa1693f2cd Greece
9c59f024-1b55-4c7f-954c-8069a5511e6f Portugal
f14d220e-aef9-42d8-8bcc-03bc58528a3c Spain
283406d6-c2df-46a1-91f0-c230e668b4fa Finland
056ea954-00c9-48e4-be35-dbfc3ee687e9 Belgium
8fd7c910-fbcf-49c0-a561-ead5ab5f2862 Italy
49825151-4c01-427e-a00b-7698594088f2 Denmark
68adf577-1672-4d1a-a553-3642ad614362 Germany
910d0247-288e-4a17-aa0f-b5021552b469 Croatia
c5ba9d4c-04f6-4739-8eb5-ecdad7caad65 Czech Republic
52029c19-84ef-4600-86e1-d3cfc82ecb72 Bulgaria
4e18e19e-8a6d-4c84-9311-779c3b7f88da Sweden
51a03e87-9ce8-4b45-8554-4515476bd870 Poland
cfc6ba7f-17d5-482a-9a9f-01fd3ef91047 France
274ec7be-1bb8-40e9-ba0a-a941c7477ff5 Sweden
e8814343-5757-4823-818c-3235209edffc Germany
552e7560-16eb-44ad-922b-e4b9fda30832 Germany
6b4ebdff-859b-4e97-86f3-2dbcd41a3a5b Hungary
5bc2e6a1-266c-40c8-b71c-ee13c6cdf12c Germany
d7b62b42-47ae-4d94-87de-e93def0da041 Poland
f5d8d1fc-8bf8-48c5-bfdb-20cef1721db8 Belgium
41d365b9-6787-41d9-8e0e-bc7c12f402f2 Norway
1b310530-6a78-45e8-9afb-ec052a4c4935 Germany
94f6a63c-786b-43d1-99a4-941a55113656 Poland
9a382b80-274b-482a-93d3-78f69d135dbd Netherlands
c2c5f2f9-f229-4952-942b-6dc8c6686ea8 Hungary
bb467480-aa41-4817-8b2d-d219427d26de Estonia
f672d4df-567d-4a50-adfb-77fa1693f2cd Greece
9c59f024-1b55-4c7f-954c-8069a5511e6f Portugal
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Yes
FSC Recycled Paper - 94.6 %
Recycled Metal - 28.2 %
Certificates and Declarations
Container Information
box 1 piece
150 mm
150 mm
97 mm
1.07 kg
3471523132313
box 10 piece
250 mm
300 mm
300 mm
10.7 kg
External Classifications and Standards
Q
EC000066 - Power contactor, AC switching
EC000066 - Power contactor, AC switching
EC000066 - Power contactor, AC switching
V11.0 : 27371003
39121529
4758 >> Iec Contactors
3707014
3210037

Ordering
Popular Downloads
Dimensions
140 mm
180.5 mm
227 mm
5.05 kg
Technical
3
0
1
1
3P
Main Circuit 690 V
Main Circuit 50 / 60 Hz
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 350 A
(690 V) 40 °C 350 A
(690 V) 55 °C 300 A
(690 V) 70 °C 240 A
(690 V) 40 °C 350 A
(690 V) 55 °C 300 A
(690 V) 70 °C 240 A
(415 V) 55 °C 210 A
(440 V) 55 °C 210 A
(500 V) 55 °C 210 A
(690 V) 55 °C 210 A
(380 / 400 V) 55 °C 210 A
(220 / 230 / 240 V) 55 °C 210
(415 V) 55 °C 210 A
(440 V) 55 °C 210 A
(500 V) 55 °C 210 A
(690 V) 55 °C 210 A
(380 / 400 V) 55 °C 210 A
(220 / 230 / 240 V) 55 °C 210
(110 V) 2 Poles in Series, 40 °C 350 A
(220 V) 3 Poles in Series, 40 °C 350 A
(110 V) 2 Poles in Series, 40 °C 350 A
(220 V) 3 Poles in Series, 40 °C 350 A
(110 V) 2 Poles in Series, 40 °C 350 A
(220 V) 3 Poles in Series, 40 °C 350 A
(110 V) 2 Poles in Series, 40 °C 350 A
(220 V) 3 Poles in Series, 40 °C 350 A
(110 V) 2 Poles in Series, 40 °C 350 A
(220 V) 3 Poles in Series, 40 °C 350 A
(110 V) 2 Poles in Series, 40 °C 350 A
(220 V) 3 Poles in Series, 40 °C 350 A
(415 V) 110 kW
(440 V) 110 kW
(500 V) 132 kW
(690 V) 160 kW
(380 / 400 V) 110 kW
(220 / 230 / 240 V) 59 kW
(415 V) 110 kW
(440 V) 110 kW
(500 V) 132 kW
(690 V) 160 kW
(380 / 400 V) 110 kW
(220 / 230 / 240 V) 59 kW
8 x Ie AC-3
10 x Ie AC-3
gG Type Fuses 400 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 1700 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 400 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 1000 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 2500 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 1200 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 1700 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 400 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 1000 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 2500 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 1200 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 2200 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 2000 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 2200 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 2000 A
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
acc. to UL/CSA 600 V
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
acc. to UL/CSA 600 V
Main Circuit 8 kV
(AC-1) 300 cycles per hour
(AC-2 / AC-4) 150 cycles per hour
(AC-3) 300 cycles per hour
(AC-1) 300 cycles per hour
(AC-2 / AC-4) 150 cycles per hour
(AC-3) 300 cycles per hour
5 million
300 cycles per hour
(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
50 Hz 100 ... 250 V
60 Hz 100 ... 250 V
DC Operation 100 ... 250 V
50 Hz 100 ... 250 V
60 Hz 100 ... 250 V
DC Operation 100 ... 250 V
Holding at Max. Rated Control Circuit Voltage 50 Hz 10 V·A
Holding at Max. Rated Control Circuit Voltage 60 Hz 10 V·A
Holding at Max. Rated Control Circuit Voltage DC 2 W
Pull-in at Max. Rated Control Circuit Voltage 50 Hz 470 V·A
Pull-in at Max. Rated Control Circuit Voltage 60 Hz 470 V·A
Pull-in at Max. Rated Control Circuit Voltage DC 520 W
Holding at Max. Rated Control Circuit Voltage 50 Hz 10 V·A
Holding at Max. Rated Control Circuit Voltage 60 Hz 10 V·A
Holding at Max. Rated Control Circuit Voltage DC 2 W
Pull-in at Max. Rated Control Circuit Voltage 50 Hz 470 V·A
Pull-in at Max. Rated Control Circuit Voltage 60 Hz 470 V·A
Pull-in at Max. Rated Control Circuit Voltage DC 520 W
at Rated Operating Conditions per Pole 9 W
Between Coil De-energization and NC Contact Closing 40 .... 50 ms
Between Coil De-energization and NO Contact Opening 43 ... 53 ms
Between Coil Energization and NC Contact Opening 45 ... 85 ms
Between Coil Energization and NO Contact Closing 50 ... 90 ms
Between Coil De-energization and NC Contact Closing 40 .... 50 ms
Between Coil De-energization and NO Contact Opening 43 ... 53 ms
Between Coil Energization and NC Contact Opening 45 ... 85 ms
Between Coil Energization and NO Contact Closing 50 ... 90 ms
Bar 32 mm²
Rigid Al-Cable 2 x 95 ... 120 mm²
Rigid Cu-Cable 16 ... 240 mm²
Bar 32 mm²
Rigid Al-Cable 2 x 95 ... 120 mm²
Rigid Cu-Cable 16 ... 240 mm²
Flexible with Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible 2x0.75 ... 2.5 mm²
Solid 2 x 1 ... 4 mm²
Stranded 2 x 1 .... 4 mm²
Flexible with Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible 2x0.75 ... 2.5 mm²
Solid 2 x 1 ... 4 mm²
Stranded 2 x 1 .... 4 mm²
Bar 32 mm²
Rigid Al-Cable 2 x 95 ... 120 mm²
Rigid Cu-Cable 16 ... 240 mm²
Bar 32 mm²
Rigid Al-Cable 2 x 95 ... 120 mm²
Rigid Cu-Cable 16 ... 240 mm²
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Main Circuit 18 N·m
Main Circuit: Bars
Block Contactor
Technical UL/CSA
Main Circuit 600 V
(600 V AC) 300 A
(200 V AC) Three Phase 60 hp
(208 V AC) Three Phase 60 hp
(220 ... 240 V AC) Three Phase 75 hp
(440 ... 480 V AC) Three Phase 150 hp
(550 ... 600 V AC) Three Phase 200 hp
(200 V AC) Three Phase 60 hp
(208 V AC) Three Phase 60 hp
(220 ... 240 V AC) Three Phase 75 hp
(440 ... 480 V AC) Three Phase 150 hp
(550 ... 600 V AC) Three Phase 200 hp
(440 ... 480 V AC) Three Phase 180 A
(550 ... 600 V AC) Three Phase 192 A
(440 ... 480 V AC) Three Phase 180 A
(550 ... 600 V AC) Three Phase 192 A
Environmental
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C
Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C
Close to Contactor for Storage -40 ... 70 °C
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C
Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C
Close to Contactor for Storage -40 ... 70 °C
Without Derating 3000 m
Shock Direction: A 5 g
Shock Direction: B1 5 g
Shock Direction: B2 5 g
Shock Direction: C1 5 g
Shock Direction: C2 5 g
Shock Direction: A 5 g
Shock Direction: B1 5 g
Shock Direction: B2 5 g
Shock Direction: C1 5 g
Shock Direction: C2 5 g
Material Compliance
Following EU Directive 2011/65/EU
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
Certificates and Declarations
Container Information
box 1 piece
203 mm
245 mm
188 mm
5.75 kg
7320500220276
External Classifications and Standards
Q
EC000066 - Power contactor, AC switching
EC000066 - Power contactor, AC switching
EC000066 - Power contactor, AC switching
V11.0 : 27371003
39121529
4755 >> Contactors
3709247
4115275
3228306

Ordering
1 piece
85364900
Popular Downloads
Dimensions
105 mm
152 mm
196 mm
2.4 kg
Technical
3
0
1
1
3P
Main Circuit 1000 V
Main Circuit 50 / 60 Hz
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 350 A
(1000 V) 40 °C 275 A
(1000 V) 55 °C 250 A
(1000 V) 60 °C 250 A
(1000 V) 70 °C 200 A
(690 V) 40 °C 350 A
(690 V) 55 °C 300 A
(690 V) 70 °C 240 A
(1000 V) 40 °C 275 A
(1000 V) 55 °C 250 A
(1000 V) 60 °C 250 A
(1000 V) 70 °C 200 A
(690 V) 40 °C 350 A
(690 V) 55 °C 300 A
(690 V) 70 °C 240 A
(415 V) 55 °C 205 A
(440 V) 55 °C 205 A
(500 V) 55 °C 186 A
(690 V) 55 °C 165 A
(1000 V) 55 °C 100 A
(380 / 400 V) 55 °C 205 A
(220 / 230 / 240 V) 55 °C 205 A
(415 V) 55 °C 205 A
(440 V) 55 °C 205 A
(500 V) 55 °C 186 A
(690 V) 55 °C 165 A
(1000 V) 55 °C 100 A
(380 / 400 V) 55 °C 205 A
(220 / 230 / 240 V) 55 °C 205 A
(110 V) 2 Poles in Series, 40 °C 275 A
(220 V) 3 Poles in Series, 40 °C 275 A
(110 V) 2 Poles in Series, 40 °C 275 A
(220 V) 3 Poles in Series, 40 °C 275 A
(110 V) 2 Poles in Series, 40 °C 275 A
(220 V) 3 Poles in Series, 40 °C 275 A
(110 V) 2 Poles in Series, 40 °C 275 A
(220 V) 3 Poles in Series, 40 °C 275 A
(110 V) 2 Poles in Series, 40 °C 275 A
(220 V) 3 Poles in Series, 40 °C 275 A
(110 V) 2 Poles in Series, 40 °C 275 A
(220 V) 3 Poles in Series, 40 °C 275 A
(415 V) 110 kW
(440 V) 132 kW
(500 V) 132 kW
(690 V) 160 kW
(1000 V) 132 kW
(380 / 400 V) 110 kW
(220 / 230 / 240 V) 55 kW
(415 V) 110 kW
(440 V) 132 kW
(500 V) 132 kW
(690 V) 160 kW
(1000 V) 132 kW
(380 / 400 V) 110 kW
(220 / 230 / 240 V) 55 kW
8 x Ie AC-3
10 x Ie AC-3
gG Type Fuses 400 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 1640 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 350 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 670 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 2050 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 947 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 1640 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 350 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 670 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 2050 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 947 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 3500 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 2500 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 3500 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 2500 A
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
acc. to UL/CSA 1000 V
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
acc. to UL/CSA 1000 V
Main Circuit 8 kV
(AC-1) 300 cycles per hour
(AC-2 / AC-4) 150 cycles per hour
(AC-3) 300 cycles per hour
(AC-1) 300 cycles per hour
(AC-2 / AC-4) 150 cycles per hour
(AC-3) 300 cycles per hour
5 million
300 cycles per hour
(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
50 Hz 100 ... 250 V
60 Hz 100 ... 250 V
DC Operation 100 ... 250 V
50 Hz 100 ... 250 V
60 Hz 100 ... 250 V
DC Operation 100 ... 250 V
Holding at Max. Rated Control Circuit Voltage 50 Hz 7 V·A
Holding at Max. Rated Control Circuit Voltage 60 Hz 7 V·A
Holding at Max. Rated Control Circuit Voltage DC 2.5 W
Pull-in at Max. Rated Control Circuit Voltage 50 Hz 220 V·A
Pull-in at Max. Rated Control Circuit Voltage 60 Hz 220 V·A
Pull-in at Max. Rated Control Circuit Voltage DC 190 W
Holding at Max. Rated Control Circuit Voltage 50 Hz 7 V·A
Holding at Max. Rated Control Circuit Voltage 60 Hz 7 V·A
Holding at Max. Rated Control Circuit Voltage DC 2.5 W
Pull-in at Max. Rated Control Circuit Voltage 50 Hz 220 V·A
Pull-in at Max. Rated Control Circuit Voltage 60 Hz 220 V·A
Pull-in at Max. Rated Control Circuit Voltage DC 190 W
at Rated Operating Conditions per Pole 8 W
Between Coil De-energization and NO Contact Opening 37 ... 47 ms
Between Coil Energization and NO Contact Closing 25 ... 55 ms
Between Coil De-energization and NO Contact Opening 37 ... 47 ms
Between Coil Energization and NO Contact Closing 25 ... 55 ms
Flexible 2 x 50 ... 95 mm²
Rigid Al-Cable 1 x 95 ... 185 mm²
Rigid Cu-Cable 1 x 6 ... 150 mm²
Flexible 2 x 50 ... 95 mm²
Rigid Al-Cable 1 x 95 ... 185 mm²
Rigid Cu-Cable 1 x 6 ... 150 mm²
Flexible with Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm²
Flexible 2x0.75 ... 2.5 mm²
Solid 1 x 1 ... 4 mm²
Stranded 1 x 1 .... 4 mm²
Flexible with Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm²
Flexible 2x0.75 ... 2.5 mm²
Solid 1 x 1 ... 4 mm²
Stranded 1 x 1 .... 4 mm²
Flexible 2 x 50 ... 95 mm²
Rigid Al-Cable 1 x 95 ... 185 mm²
Rigid Cu-Cable 2 x 50 ... 120 mm²
Flexible 2 x 50 ... 95 mm²
Rigid Al-Cable 1 x 95 ... 185 mm²
Rigid Cu-Cable 2 x 50 ... 120 mm²
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Cable Lug 18 N·m
Main Circuit 14 ... 31 N·m
Cable Lug 18 N·m
Main Circuit 14 ... 31 N·m
Main Circuit: Bars
Block Contactor
Technical UL/CSA
Main Circuit 1000 V
(1000 V AC) 275 A
(200 V AC) Three Phase 60 hp
(208 V AC) Three Phase 60 hp
(220 ... 240 V AC) Three Phase 75 hp
(440 ... 480 V AC) Three Phase 150 hp
(550 ... 600 V AC) Three Phase 200 hp
(200 V AC) Three Phase 60 hp
(208 V AC) Three Phase 60 hp
(220 ... 240 V AC) Three Phase 75 hp
(440 ... 480 V AC) Three Phase 150 hp
(550 ... 600 V AC) Three Phase 200 hp
(440 ... 480 V AC) Three Phase 180 A
(550 ... 600 V AC) Three Phase 192 A
(440 ... 480 V AC) Three Phase 180 A
(550 ... 600 V AC) Three Phase 192 A
Environmental
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C
Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C
Close to Contactor for Storage -40 ... 70 °C
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C
Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C
Close to Contactor for Storage -40 ... 70 °C
Without Derating 3000 m
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Yes
Non-hazardous waste is sent to a landfill, where there is no alternative option available within 100km of a facility
Product Efficiency - Product requires less energy to operate compared to similar product on market or older products from the same line
Design for Closing Resource Loops - Standard EN45555 - 79.2 %
Recycled Metal - 35 %
Certificates and Declarations
Container Information
box 1 piece
160 mm
258 mm
235 mm
3 kg
7320500480564
External Classifications and Standards
Q
EC000066 - Power contactor, AC switching
EC000066 - Power contactor, AC switching
EC000066 - Power contactor, AC switching
V11.0 : 27371003
39121529
4758 >> Iec Contactors
3706462
4117641
3210147

Ordering
1 piece
85364900
Popular Downloads
Dimensions
140 mm
180 mm
225 mm
3.9 kg
Technical
3
0
1
1
3P
Main Circuit 1000 V
Main Circuit 50 / 60 Hz
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 400 A
(1000 V) 40 °C 350 A
(1000 V) 55 °C 300 A
(1000 V) 60 °C 300 A
(1000 V) 70 °C 240 A
(690 V) 40 °C 400 A
(690 V) 55 °C 350 A
(690 V) 70 °C 290 A
(1000 V) 40 °C 350 A
(1000 V) 55 °C 300 A
(1000 V) 60 °C 300 A
(1000 V) 70 °C 240 A
(690 V) 40 °C 400 A
(690 V) 55 °C 350 A
(690 V) 70 °C 290 A
(415 V) 55 °C 265 A
(440 V) 55 °C 265 A
(500 V) 55 °C 250 A
(690 V) 55 °C 250 A
(1000 V) 55 °C 113 A
(380 / 400 V) 55 °C 265 A
(220 / 230 / 240 V) 55 °C 265 A
(415 V) 55 °C 265 A
(440 V) 55 °C 265 A
(500 V) 55 °C 250 A
(690 V) 55 °C 250 A
(1000 V) 55 °C 113 A
(380 / 400 V) 55 °C 265 A
(220 / 230 / 240 V) 55 °C 265 A
(110 V) 2 Poles in Series, 40 °C 350 A
(220 V) 3 Poles in Series, 40 °C 350 A
(110 V) 2 Poles in Series, 40 °C 350 A
(220 V) 3 Poles in Series, 40 °C 350 A
(110 V) 2 Poles in Series, 40 °C 350 A
(220 V) 3 Poles in Series, 40 °C 350 A
(110 V) 2 Poles in Series, 40 °C 350 A
(220 V) 3 Poles in Series, 40 °C 350 A
(110 V) 2 Poles in Series, 40 °C 350 A
(220 V) 3 Poles in Series, 40 °C 350 A
(110 V) 2 Poles in Series, 40 °C 350 A
(220 V) 3 Poles in Series, 40 °C 350 A
(415 V) 132 kW
(440 V) 160 kW
(500 V) 160 kW
(690 V) 200 kW
(1000 V) 160 kW
(380 / 400 V) 132 kW
(220 / 230 / 240 V) 75 kW
(415 V) 132 kW
(440 V) 160 kW
(500 V) 160 kW
(690 V) 200 kW
(1000 V) 160 kW
(380 / 400 V) 132 kW
(220 / 230 / 240 V) 75 kW
8 x Ie AC-3
10 x Ie AC-3
gG Type Fuses 500 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 2120 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 400 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 865 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 2650 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 1224 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 2120 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 400 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 865 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 2650 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 1224 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 3800 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 3300 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 3800 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 3300 A
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
acc. to UL/CSA 1000 V
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
acc. to UL/CSA 1000 V
Main Circuit 8 kV
(AC-1) 300 cycles per hour
(AC-2 / AC-4) 150 cycles per hour
(AC-3) 300 cycles per hour
(AC-1) 300 cycles per hour
(AC-2 / AC-4) 150 cycles per hour
(AC-3) 300 cycles per hour
5 million
300 cycles per hour
(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
50 Hz 100 ... 250 V
60 Hz 100 ... 250 V
DC Operation 100 ... 250 V
50 Hz 100 ... 250 V
60 Hz 100 ... 250 V
DC Operation 100 ... 250 V
Holding at Max. Rated Control Circuit Voltage 50 Hz 17.5 V·A
Holding at Max. Rated Control Circuit Voltage 60 Hz 17.5 V·A
Holding at Max. Rated Control Circuit Voltage DC 4.5 W
Pull-in at Max. Rated Control Circuit Voltage 50 Hz 385 V·A
Pull-in at Max. Rated Control Circuit Voltage 60 Hz 385 V·A
Pull-in at Max. Rated Control Circuit Voltage DC 410 W
Holding at Max. Rated Control Circuit Voltage 50 Hz 17.5 V·A
Holding at Max. Rated Control Circuit Voltage 60 Hz 17.5 V·A
Holding at Max. Rated Control Circuit Voltage DC 4.5 W
Pull-in at Max. Rated Control Circuit Voltage 50 Hz 385 V·A
Pull-in at Max. Rated Control Circuit Voltage 60 Hz 385 V·A
Pull-in at Max. Rated Control Circuit Voltage DC 410 W
at Rated Operating Conditions per Pole 14 W
Between Coil De-energization and NO Contact Opening 37 ... 47 ms
Between Coil Energization and NO Contact Closing 25 ... 55 ms
Between Coil De-energization and NO Contact Opening 37 ... 47 ms
Between Coil Energization and NO Contact Closing 25 ... 55 ms
Flexible 2 x 70 ... 185 mm²
Rigid Al-Cable 1 x 185 ... 240 mm²
Rigid Cu-Cable 2 x 70 ... 185 mm²
Flexible 2 x 70 ... 185 mm²
Rigid Al-Cable 1 x 185 ... 240 mm²
Rigid Cu-Cable 2 x 70 ... 185 mm²
Flexible with Ferrule 2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm²
Flexible 2x0.75 ... 2.5 mm²
Solid 2 x 1 ... 4 mm²
Stranded 1 x 1 .... 4 mm²
Flexible with Ferrule 2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm²
Flexible 2x0.75 ... 2.5 mm²
Solid 2 x 1 ... 4 mm²
Stranded 1 x 1 .... 4 mm²
Flexible 1 x 16 ... 240 mm²
Rigid Al-Cable 1 x 185 ... 240 mm²
Rigid Cu-Cable 2 x 70 ... 185 mm²
Flexible 1 x 16 ... 240 mm²
Rigid Al-Cable 1 x 185 ... 240 mm²
Rigid Cu-Cable 2 x 70 ... 185 mm²
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Cable Lug 28 N·m
Main Circuit 22 ... 43 N·m
Cable Lug 28 N·m
Main Circuit 22 ... 43 N·m
Main Circuit: Bars
Block Contactor
Technical UL/CSA
5
270 A
(200 V AC) Three Phase 75 Hp
(230 V AC) Three Phase 100 Hp
(460 V AC) Three Phase 200 Hp
(575 V AC) Three Phase 200 Hp
(200 V AC) Three Phase 75 Hp
(230 V AC) Three Phase 100 Hp
(460 V AC) Three Phase 200 Hp
(575 V AC) Three Phase 200 Hp
Main Circuit 1000 V
(1000 V AC) 350 A
(200 V AC) Three Phase 75 hp
(208 V AC) Three Phase 75 hp
(220 ... 240 V AC) Three Phase 100 hp
(440 ... 480 V AC) Three Phase 200 hp
(550 ... 600 V AC) Three Phase 250 hp
(200 V AC) Three Phase 75 hp
(208 V AC) Three Phase 75 hp
(220 ... 240 V AC) Three Phase 100 hp
(440 ... 480 V AC) Three Phase 200 hp
(550 ... 600 V AC) Three Phase 250 hp
(440 ... 480 V AC) Three Phase 240 A
(550 ... 600 V AC) Three Phase 242 A
(440 ... 480 V AC) Three Phase 240 A
(550 ... 600 V AC) Three Phase 242 A
Environmental
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C
Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C
Close to Contactor for Storage -40 ... 70 °C
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C
Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C
Close to Contactor for Storage -40 ... 70 °C
Without Derating 3000 m
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Yes
Non-hazardous waste is sent to a landfill, where there is no alternative option available within 100km of a facility
Product Efficiency - Product considered more energy-efficient compared to similar product on market or older products from the same line
Design for Closing Resource Loops - Standard EN45555 - 76.3 %
Recycled Metal - 33 %
Certificates and Declarations
Container Information
box 1 piece
263 mm
203 mm
289 mm
4.6 kg
7320500481189
External Classifications and Standards
Q
EC000066 - Power contactor, AC switching
EC000066 - Power contactor, AC switching
EC000066 - Power contactor, AC switching
V11.0 : 27371003
39121529
4758 >> Iec Contactors
3706474
4117646
3210155

ABB EcoSolutions
Yes
UL 2799 Zero Waste To Landfill Validation available
Design for Closing Resource Loops - Standard EN45555 - 56.6 %
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
c29a751a-be17-4df0-832b-bc41e0056527 Italy
2a076d25-5885-439c-a2e6-562a12b90198 Germany
a16b56d1-dc99-4c55-991d-e62075649be4 Poland
dfa380c0-88d1-44e8-af7c-e93b491cd27e Netherlands
000182ba-09df-4f4a-98fe-0e65e416447e Estonia
d7fb814f-534f-4706-9149-d5b6e015862e Greece
a34ffad3-0654-4dbf-9a2f-b75b6deeab05 Portugal
9c31c87a-6577-4cf2-bff2-c659d2cf4713 Bulgaria
79b8eb5a-a8e6-4b80-8e98-4334c54b8e4c Sweden
9daa2fe5-d7c4-47cb-bc82-54a00264a086 Denmark
8d27fed3-357b-428d-979b-bd2bc3977046 Poland
ab930018-740a-410f-8c3b-e92c9c0ec4f3 France
b215cde0-c453-44a0-9aa2-b68b61004cb4 Germany
24dff1fc-a989-4f93-9843-7650391183e8 Norway
1c4970d6-6ba9-477c-bfc1-915880cf6b27 Finland
419d4f23-39e0-4f3e-ba0d-19a2cbc2fd0d Netherlands
4d2c6bbe-8ade-448c-8147-77a16c403875 Germany
517f22a2-ece3-48fc-a690-b648e4136f31 Netherlands
e27935fd-02aa-4246-a5db-a765ca2c2038 Croatia
c5b64a1c-2eb4-40cf-b9d1-83c1532e04bb Czech Republic
393488f6-8465-4fa4-966f-dc34e6482b65 Sweden
9e68334a-59d9-4bbf-a724-516447abb72b Germany
054c53f3-09ac-4472-a9ff-0daddffcab29 Poland
a40abdb3-7c61-4d82-8639-25e8b744f038 Germany
bb00608f-06a1-4498-8dc3-106fc600396d France
cc2c475a-5ea9-4b8f-94d7-b8bc65721e28 Netherlands
81f7af18-dc48-4a22-8cf6-aac1eb368d2c Spain
3dea16fd-bfa8-4e70-8369-cb90cf81f797 Netherlands
2a076d25-5885-439c-a2e6-562a12b90198 Germany
a16b56d1-dc99-4c55-991d-e62075649be4 Poland
dfa380c0-88d1-44e8-af7c-e93b491cd27e Netherlands
000182ba-09df-4f4a-98fe-0e65e416447e Estonia
d7fb814f-534f-4706-9149-d5b6e015862e Greece
a34ffad3-0654-4dbf-9a2f-b75b6deeab05 Portugal
9c31c87a-6577-4cf2-bff2-c659d2cf4713 Bulgaria
79b8eb5a-a8e6-4b80-8e98-4334c54b8e4c Sweden
9daa2fe5-d7c4-47cb-bc82-54a00264a086 Denmark
8d27fed3-357b-428d-979b-bd2bc3977046 Poland
Environmental
Ordering
XT3NE3200AFF000XXX
3641004
4309662
8015644019297
1 piece
85362090
Dimensions
105 mm
150 mm
70 mm
1.7 kg
Container Information
box 1 piece
155 mm
190 mm
155 mm
1.723 kg
8015644019297
Additional Information
Power Distribution
SACE Tmax XT
Moulded Case Circuit Breaker
Automatic Circuit Breaker
F
Technical
Busbar 85..192 mm²
AC/DC
120 cycles per hour
8000 cycle
120 cycles per hour
8000 cycle
240 cycles per hour
25000 cycle
240 cycles per hour
25000 cycle
3P
CB with SOR 30 ms
CB with UVR 30 ms
CB with SOR 30 ms
CB with UVR 30 ms
1 piece
at Rated Operating Conditions per Pole 13.2 W
200 A
50 / 60 Hz
8 kV
2000 A
800 V
690 V AC
500 V DC
690 V AC
500 V DC
(220 V AC) 50 kA
(230 V AC) 50 kA
(240 V AC) 50 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 18 kA
(500 V AC) 15 kA
(525 V AC) 9,75 kA
(690 V AC) 3,75 kA
(250 V DC) 2 Poles in Series 36 kA
(500 V DC) 2 Poles in Series 50 kA
(220 V AC) 50 kA
(230 V AC) 50 kA
(240 V AC) 50 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 18 kA
(500 V AC) 15 kA
(525 V AC) 9,75 kA
(690 V AC) 3,75 kA
(250 V DC) 2 Poles in Series 36 kA
(220 V AC) 50 kA
(230 V AC) 50 kA
(240 V AC) 50 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 36 kA
(500 V AC) 20 kA
(525 V AC) 13 kA
(690 V AC) 5 kA
(250 V DC) 2 Poles in Series 36 kA
(500 V DC) 3 Poles in Series 50 kA
(220 V AC) 50 kA
(230 V AC) 50 kA
(240 V AC) 50 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 36 kA
(500 V AC) 20 kA
(525 V AC) 13 kA
(690 V AC) 5 kA
(250 V DC) 2 Poles in Series 36 kA
250 A
690 V
Main Circuit M8
TMD
TM
140...200 A
N
IEC60947-2
XT3
Front
Bolt
8 N·m
Certificates and Declarations
External Classifications and Standards
EC000228 - Power circuit-breaker for trafo/generator/installation protection
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Q
39120000
5. Small Equipment (No External Dimension More Than 50 cm)
V11.1 : 27370409

ABB EcoSolutions
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Environmental
Ordering
ZEACG
4381723
8015644776206
1 piece
85389099
Dimensions
105 mm
55 mm
135 mm
0.12 kg
Container Information
box 1 piece
105 mm
55 mm
135 mm
0.42 kg
8015644776206
Additional Information
Accessories for Emax 2, Accessories for Tmax XT
Accessory
Accessory
XT7-XT7M, E1.2, E2.2, E4.2, E6.2
SACE Tmax XT, SACE Emax 2
Technical
Loose or configurable
AC/DC
1 piece
220...240 V
IEC
Certificates and Declarations
External Classifications and Standards
EC002483 - Switch spool for power circuit breaker
EC002483 - Switch spool for power circuit breaker
5219 >> Switch part or accessory
Q
39121601
5. Small Equipment (No External Dimension More Than 50 cm)
V11.1 : 27370421

ABB EcoSolutions
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Environmental
Ordering
KXTFYOCFPD
3642166
4381340
8015644070267
1 piece
85389099
Dimensions
0.17 kg
Container Information
box 1 piece
110 mm
60 mm
140 mm
0.2 kg
8015644070267
Additional Information
Accessories for Tmax XT
Accessory
Accessory
XT5
XT6
XT5
XT6
SACE Tamx XT
Technical
Loose or configurable
AC/DC
1 piece
110...240 V AC
110...250 V DC
110...240 V AC
110...250 V DC
IEC60947-2
UL489
IEC60947-2
UL489
Certificates and Declarations
External Classifications and Standards
EC002483 - Switch spool for power circuit breaker
EC002483 - Switch spool for power circuit breaker
4879 >> Shunt release (for power circuit breaker)
39121601
5. Small Equipment (No External Dimension More Than 50 cm)
V11.1 : 27370421

Ordering
1 piece
85364900
Popular Downloads
Dimensions
90 mm
126 mm
150 mm
1.55 kg
Technical
3
0
1
1
3P
Main Circuit 690 V
Main Circuit 50 / 60 Hz
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 160 A
(690 V) 40 °C 160 A
(690 V) 60 °C 145 A
(690 V) 70 °C 130 A
(690 V) 40 °C 160 A
(690 V) 60 °C 145 A
(690 V) 70 °C 130 A
(415 V) 55 °C 116 A
(440 V) 55 °C 116 A
(500 V) 55 °C 110 A
(690 V) 55 °C 65 A
(380 / 400 V) 55 °C 116 A
(220 / 230 / 240 V) 55 °C 116 A
(415 V) 55 °C 116 A
(440 V) 55 °C 116 A
(500 V) 55 °C 110 A
(690 V) 55 °C 65 A
(380 / 400 V) 55 °C 116 A
(220 / 230 / 240 V) 55 °C 116 A
(415 V) 60 °C 116 A
(440 V) 60 °C 116 A
(500 V) 60 °C 110 A
(690 V) 60 °C 65 A
(380 / 400 V) 60 °C 116 A
(220 / 230 / 240 V) 60 °C 116 A
(415 V) 60 °C 116 A
(440 V) 60 °C 116 A
(500 V) 60 °C 110 A
(690 V) 60 °C 65 A
(380 / 400 V) 60 °C 116 A
(220 / 230 / 240 V) 60 °C 116 A
(110 V) 2 Poles in Series, 40 °C 145 A
(220 V) 3 Poles in Series, 40 °C 145 A
(110 V) 2 Poles in Series, 40 °C 145 A
(220 V) 3 Poles in Series, 40 °C 145 A
(110 V) 2 Poles in Series, 40 °C 145 A
(220 V) 3 Poles in Series, 40 °C 145 A
(110 V) 2 Poles in Series, 40 °C 145 A
(220 V) 3 Poles in Series, 40 °C 145 A
(110 V) 2 Poles in Series, 40 °C 145 A
(220 V) 3 Poles in Series, 40 °C 145 A
(110 V) 2 Poles in Series, 40 °C 145 A
(220 V) 3 Poles in Series, 40 °C 145 A
(415 V) 55 kW
(440 V) 75 kW
(500 V) 75 kW
(690 V) 55 kW
(380 / 400 V) 55 kW
(220 / 230 / 240 V) 30 kW
(415 V) 55 kW
(440 V) 75 kW
(500 V) 75 kW
(690 V) 55 kW
(380 / 400 V) 55 kW
(220 / 230 / 240 V) 30 kW
(415 V) 55 kW
(440 V) 75 kW
(500 V) 75 kW
(690 V) 55 kW
(380 / 400 V) 55 kW
(220 / 230 / 240 V) 30 kW
(415 V) 55 kW
(440 V) 75 kW
(500 V) 75 kW
(690 V) 55 kW
(380 / 400 V) 55 kW
(220 / 230 / 240 V) 30 kW
8 x Ie AC-3
8.5 x Ie AC-3e
10 x Ie AC-3
12 x Ie AC-3e
gG Type Fuses 250 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 928 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 160 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 379 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1160 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 536 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 928 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 160 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 379 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1160 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 536 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 2000 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 1000 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 2000 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 1000 A
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
acc. to UL/CSA 600 V
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
acc. to UL/CSA 600 V
Main Circuit 8 kV
(AC-1) 300 cycles per hour
(AC-2 / AC-4) 150 cycles per hour
(AC-3) 300 cycles per hour
(AC-1) 300 cycles per hour
(AC-2 / AC-4) 150 cycles per hour
(AC-3) 300 cycles per hour
5 million
300 cycles per hour
(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
50 Hz 24 ... 60 V
60 Hz 24 ... 60 V
DC Operation 20 ... 60 V
50 Hz 24 ... 60 V
60 Hz 24 ... 60 V
DC Operation 20 ... 60 V
Holding at Max. Rated Control Circuit Voltage 50 Hz 5.5 V·A
Holding at Max. Rated Control Circuit Voltage 60 Hz 5.5 V·A
Holding at Max. Rated Control Circuit Voltage DC 2.5 W
Pull-in at Max. Rated Control Circuit Voltage 50 Hz 225 V·A
Pull-in at Max. Rated Control Circuit Voltage 60 Hz 225 V·A
Pull-in at Max. Rated Control Circuit Voltage DC 210 W
Holding at Max. Rated Control Circuit Voltage 50 Hz 5.5 V·A
Holding at Max. Rated Control Circuit Voltage 60 Hz 5.5 V·A
Holding at Max. Rated Control Circuit Voltage DC 2.5 W
Pull-in at Max. Rated Control Circuit Voltage 50 Hz 225 V·A
Pull-in at Max. Rated Control Circuit Voltage 60 Hz 225 V·A
Pull-in at Max. Rated Control Circuit Voltage DC 210 W
at Rated Operating Conditions per Pole 6 W
Between Coil De-energization and NO Contact Opening 37 ... 47 ms
Between Coil Energization and NO Contact Closing 25 ... 55 ms
Between Coil De-energization and NO Contact Opening 37 ... 47 ms
Between Coil Energization and NO Contact Closing 25 ... 55 ms
Flexible 1 x 10 ... 70 mm²
Rigid Cu-Cable 1 x 10 ... 95 mm²
Flexible 1 x 10 ... 70 mm²
Rigid Cu-Cable 1 x 10 ... 95 mm²
Flexible with Ferrule 2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm²
Flexible 2x0.75 ... 2.5 mm²
Solid 1 x 1 ... 4 mm²
Stranded 2 x 1 .... 4 mm²
Flexible with Ferrule 2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm²
Flexible 2x0.75 ... 2.5 mm²
Solid 1 x 1 ... 4 mm²
Stranded 2 x 1 .... 4 mm²
Flexible 2 x 10 ... 70 mm²
Rigid Cu-Cable 2 x 10 ... 95 mm²
Flexible 2 x 10 ... 70 mm²
Rigid Cu-Cable 2 x 10 ... 95 mm²
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Cable Lug 9 N·m
Main Circuit 8 N·m
Cable Lug 9 N·m
Main Circuit 8 N·m
Double Clamp
Block Contactor
Technical UL/CSA
Main Circuit 600 V
(600 V AC) 160 A
(200 V AC) Three Phase 30 hp
(208 V AC) Three Phase 30 hp
(220 ... 240 V AC) Three Phase 40 hp
(440 ... 480 V AC) Three Phase 75 hp
(550 ... 600 V AC) Three Phase 100 hp
(200 V AC) Three Phase 30 hp
(208 V AC) Three Phase 30 hp
(220 ... 240 V AC) Three Phase 40 hp
(440 ... 480 V AC) Three Phase 75 hp
(550 ... 600 V AC) Three Phase 100 hp
(440 ... 480 V AC) Three Phase 96 A
(550 ... 600 V AC) Three Phase 99 A
(440 ... 480 V AC) Three Phase 96 A
(550 ... 600 V AC) Three Phase 99 A
Environmental
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C
Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C
Close to Contactor for Storage -40 ... 70 °C
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C
Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C
Close to Contactor for Storage -40 ... 70 °C
Without Derating 3000 m
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Yes
Non-hazardous waste is sent to a landfill, where there is no alternative option available within 100km of a facility
Product Efficiency - Product requires less energy to operate compared to similar product on market or older products from the same line
Design for Closing Resource Loops - Standard EN45555 - 87.8 %
Recycled Metal - 37 %
Certificates and Declarations
Container Information
box 1 piece
207 mm
216 mm
150 mm
1.75 kg
7320500476352
External Classifications and Standards
Q
EC000066 - Power contactor, AC switching
EC000066 - Power contactor, AC switching
EC000066 - Power contactor, AC switching
V11.0 : 27371003
39121529
4758 >> Iec Contactors
3706158
4117611
3210066

T4S box circuit breaker - Icu breaking capacity (415V) = 50kA - 250A PR222MP In = 200 3-pole with front terminals.

ABB EcoSolutions
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Environmental
Ordering
KXT1EDINRCPL
4381073
8015644010416
1 piece
85362090
Dimensions
0.207 kg
Container Information
box 1 piece
300 mm
20 mm
350 mm
0.218 kg
8015644010416
Additional Information
Accessories for Tmax XT
Accessory
Accessory
XT1
SACE Tmax XT
Technical
Loose or configurable
1 piece
IEC60947-2
Certificates and Declarations
External Classifications and Standards
EC002498 - Accessories/spare parts for low-voltage switch technology
EC002498 - Accessories/spare parts for low-voltage switch technology
3012 >> Electrical fixture brackets
Q
31162504
5. Small Equipment (No External Dimension More Than 50 cm)
V11.1 : 27371390


Material Compliance
Environmental
Ordering
8015644517694
1 piece
85389099
Dimensions
0.12 kg
Container Information
1 piece
110 mm
60 mm
140 mm
0.14 kg
8015644517694
Additional Information
Accessories for Tmax T
Accessory
ACC
T1, T2, T3
SACE Tmax T
Technical
Loose or configurable
T1-T2-T3
IEC
Certificates and Declarations
External Classifications and Standards
Q
39120000
5. Small Equipment (No External Dimension More Than 50 cm)

Ordering
1 piece
85365080
Popular Downloads
Dimensions
54 mm
65 mm
85 mm
0.405 kg
Technical
2
2
0
0
4P
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 61095
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 61095
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
Main Circuit 220 V DC
Main Circuit 400 V AC
Main Circuit 220 V DC
Main Circuit 400 V AC
Control Circuit 400 Hz
Control Circuit 50 Hz
Control Circuit 60 Hz
Control Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit DC
Control Circuit 400 Hz
Control Circuit 50 Hz
Control Circuit 60 Hz
Control Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit DC
(NC) 30 A
(NO) 40 A
(NC) 30 A
(NO) 40 A
(230 V) Single Phase, NO 22 A
(NO) 40 A
(230 V) Single Phase, NO 22 A
(230 V) Single Phase, NC 6.9 kW
(230 V) Single Phase, NO 9.2 kW
(230 V) Single Phase, NC 6.9 kW
(230 V) Single Phase, NO 9.2 kW
(230 V) Single Phase, NO 3.7 kW
(230 V) Single Phase, NC 6.9 kW
(230 V) Single Phase, NO 9.2 kW
(230 V) Single Phase, NC 6.9 kW
(230 V) Single Phase, NO 9.2 kW
(230 V) Single Phase, NO 3.7 kW
8 x Ie / AC-3
10 x Ie / AC-3
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 176 A
500 V
6 kV
AC-1 (NC) 70000 cycle
AC-1 (NO) 150000 cycle
AC-3 (NO) 100000 cycle
AC-7a (NC) 70000 cycle
AC-7a (NO) 150000 cycle
AC-7b (NO) 100000 cycle
AC-1 (NC) 70000 cycle
AC-1 (NO) 150000 cycle
AC-3 (NO) 100000 cycle
AC-7a (NC) 70000 cycle
AC-7a (NO) 150000 cycle
AC-7b (NO) 100000 cycle
(AC-1) 300 cycles per hour
(AC-3) 600 cycles per hour
(AC-7a) 300 cycles per hour
(AC-7b) 600 cycles per hour
(AC-1) 300 cycles per hour
(AC-3) 600 cycles per hour
(AC-7a) 300 cycles per hour
(AC-7b) 600 cycles per hour
Nr. Operations 1000000 cycle
(acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at θ ≤ 55 °C)
230 V
Average Holding Value 50 / 60 Hz 4.5 V·A
Average Holding Value DC 5 W
Average Pull-in Value 50 Hz 4.5 V·A
Average Pull-in Value 60 Hz 4.5 V·A
Average Pull-in Value DC 5 W
Average Holding Value 50 / 60 Hz 4.5 V·A
Average Holding Value DC 5 W
Average Pull-in Value 50 Hz 4.5 V·A
Average Pull-in Value 60 Hz 4.5 V·A
Average Pull-in Value DC 5 W
at Rated Operating Conditions AC-1 per Pole 3 W
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Flexible with Ferrule 1x 1.5 ... 16 mm²
Flexible with Ferrule 2x 1.5 ... 10 mm²
Flexible with Insulated Ferrule 1x 1.5 ... 16 mm²
Flexible with Insulated Ferrule 2x 1.5 ... 10 mm²
Flexible 1x 1.5 ... 16 mm²
Flexible 2x 1.5 ... 10 mm²
Rigid 1x 1.5 ... 25 mm²
Rigid 2x 1.5 ... 10 mm²
Flexible with Ferrule 1x 1.5 ... 16 mm²
Flexible with Ferrule 2x 1.5 ... 10 mm²
Flexible with Insulated Ferrule 1x 1.5 ... 16 mm²
Flexible with Insulated Ferrule 2x 1.5 ... 10 mm²
Flexible 1x 1.5 ... 16 mm²
Flexible 2x 1.5 ... 10 mm²
Rigid 1x 1.5 ... 25 mm²
Rigid 2x 1.5 ... 10 mm²
Flexible with Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1 mm²
Flexible 1x 1 ... 4.0 mm²
Flexible 2x 1 ... 2.5 mm²
Rigid 1x 1 ... 4 mm²
Rigid 2x 1 ... 2.5 mm²
Flexible with Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1 mm²
Flexible 1x 1 ... 4.0 mm²
Flexible 2x 1 ... 2.5 mm²
Rigid 1x 1 ... 4 mm²
Rigid 2x 1 ... 2.5 mm²
Control Circuit 7 mm
Main Circuit 13 mm
Control Circuit 7 mm
Main Circuit 13 mm
IP20
Control Circuit Pozidriv 1
Main Circuit Pozidriv 2
Control Circuit Pozidriv 1
Main Circuit Pozidriv 2
Control Circuit 0.9 N·m
Main Circuit 2.5 N·m
Control Circuit 0.9 N·m
Main Circuit 2.5 N·m
Screw Terminals
3.0
Installation Contactor
Technical UL/CSA
Main Circuit 480 V AC
(acc. to UL 240 V) 40 A
(acc. to UL 480 V) 40 A
(acc. to UL 240 V) 40 A
(acc. to UL 480 V) 40 A
(220 ... 240 V AC) Single Phase, NC 3 Hp
(220 ... 240 V AC) Single Phase, NO 3 Hp
(440 ... 480 V AC) Single Phase, NC 7.5 Hp
(440 ... 480 V AC) Single Phase, NO 7.5 Hp
(220 ... 240 V AC) Single Phase, NC 3 Hp
(220 ... 240 V AC) Single Phase, NO 3 Hp
(440 ... 480 V AC) Single Phase, NC 7.5 Hp
(440 ... 480 V AC) Single Phase, NO 7.5 Hp
Solid 16-4 AWG
Stranded 16-4 AWG
Solid 16-4 AWG
Stranded 16-4 AWG
Solid 16-10 AWG
Stranded 16-10 AWG
Solid 16-10 AWG
Stranded 16-10 AWG
Control Circuit 8 in·lb
Main Circuit 20 in·lb
Control Circuit 8 in·lb
Main Circuit 20 in·lb
(220 ... 240 V AC) Single Phase, NC 22 A
(220 ... 240 V AC) Single Phase, NO 22 A
(440 ... 480 V AC) Single Phase, NC 21 A
(440 ... 480 V AC) Single Phase, NO 21 A
(220 ... 240 V AC) Single Phase, NC 22 A
(220 ... 240 V AC) Single Phase, NO 22 A
(440 ... 480 V AC) Single Phase, NC 21 A
(440 ... 480 V AC) Single Phase, NO 21 A
Environmental
Operation -25 ... +55 °C
Storage -40 ... +80 °C
Operation -25 ... +55 °C
Storage -40 ... +80 °C
2000 m
11 ms Pulse 15g
3
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Consumer
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Yes
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
Certificates and Declarations
Container Information
box 1 piece
92 mm
57 mm
69.5 mm
0.405 kg
4013614524790
32 piece
280 mm
395 mm
210 mm
12.96 kg
4013614539183
External Classifications and Standards
Q
EC001653 - Installation contactor for distribution board
EC001653 - Installation contactor for distribution board
EC001653 - Installation contactor for distribution board
V11.0 : 27142308
39121529
4759 >> Installation contactor for distribution board
3707583
Main category name:General Automation Vendor:ABB

